Nady Systems IRW-2PA User Manual

Page 5

Advertising
background image

12

5

INSTALLATION

1. The IRW-2PA lockbox should be positioned in the room while considering the

following criteria:

• IR Sensors should be placed on either side of operating area and as close to

microphone operating area as possible. All rules of sensor installation should

be observed as per instructions 2 below.

• IRW-2PA can be easily connected to AC power.

• IRW-2PA optional features such as Aux input and hard-wired mic input can be

easily used as desired.

• IRW-2PA LED indicators can be viewed with ease.

• If placing the IRW-2PA on a table or shelf, it should be securely fastened so

that it cannot fall over or cause any damage if the transmitters accidentally fall

when inserted or removed from the case.

• If hanging on the wall, the IRW-2PA should be properly secured to a strut or

solid wall at a reasonable height (no more than 65” from the floor).

• Installation should be performed by qualified personnel using proper

hardware to ensure there is absolutely no risk of the unit falling or causing

damage of any kind.

(Nady Systems is not liable for any damage or harm caused due to improper

installation or use of this product. All installation should be done by qualified

personnel only)

2. The IRW-1S sensors can be mounted on walls using any of the wall mounts

included. To ensure proper optimum operation, observe the following installation

rules:

a. Position the IR Sensors with their front panel receptors facing the entire area

of transmitter operation. If this is a wide area, angle the receptors to cover the

maximum area range. The diagrams on the opposite page shows some suggested

positioning for the IR Sensors.

Note: The IR sensors will need to be positioned differently for each environment.

During installation, power up the IRW-2PA and have one person walk around the

desired location, with the transmitters on, while another person positions the IR

Sensors for greatest range of mobility.

b. Since the unit utilizes infrared light reflected off of room surfaces, do not mount

the sensors near a black ceiling, wall, or heavy curtains as they may limit the range

by eliminating such reflection. Mounting the sensors in an uncluttered area near a

light colored wall will provide the best operation.

c. Although the unit can be used in most brightly lit rooms, it works best if bright

lights are not shined directly on the sensors. (Note: Never operate the unit outdoors

in daylight as it will not operate properly under such conditions)

d. Never cover the IR Sensors as this will disrupt normal operation. If they become

dirty, clean with a soft cloth. Make sure the sensors are not obstructed and always

have a clear line-of-sight with the transmitters.

Additional external IR sensors can be added using the IRW-SY Multiple Sensor Y-

adapter which allows multiple sensors to be connected to each input.

See diagrams for some examples of installation (next page).

WARNING: MAKE SURE ALL POWER IS OFF TO THE IRW-2PA WHEN

CONNECTING OR DISCONNECTING THE IRW-1S IR SENSORS TO AVOID

DAMAGE TO THE UNIT. IMPROPER OPERATION WILL VOID THE WARRANTY

3. Charging

The IRW-2PA can be used to recharge one or two HT-6SC simultaneously by plac-

ing the handheld microphones directly into the Handheld Microphone Holders

(12) without removing the rechargeable batteries. Turn on the Battery Charging

Power Switch (14). When the microphone is placed in the holder, the correspond-

ing Battery Charging LED Indicator (15) on the IRW-2PA will light brightly red.

The LED indicator will light green when the batteries are fully charged.

Note: See charger section on page 9 for important charger operation information.

HT-6SC HANDHELD MICROPHONE TRANSMITTER

(1) Power LED Indicator

(2) Power Switch

(3) Battery Charging DC Input Jack

(4) IR Emitter

(5) Microphone Input Jack

(6) Volume Control

(7) Belt Clip

(8) Battery Compartment Cover

(9) Channel Selector Switch

LT-6SC BODYPACK TRANSMITTER

(1)

(5)

(2)

(9)

(8)

(4)

(6)

(7)

1. Transmitter Set-up

Slide down the Battery Compartment Cover (8), as shown, exposing the battery

compartment. Insert 2 fresh AA alkaline batteries, NiMH rechargeable batteries, or

the optional IR-BBP battery pack while observing the correct polarity as marked. Set

the Channel Selector Switch (9) to the desired channel of operation and slide the

cover back into position on the unit. Note, only one transmitter per channel can be

used simultaneously.

(Note: Make sure the transmitter is off when changing the batteries.)

(3)

Advertising