Appendix – Network Technologies SM-nXm-C5AV-LCD User Manual

Page 38

Advertising
background image

NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5

34

APPENDIX

Appendix A- Default Settings

SETTING

DEFAULT VALUE

Login Username

Administrator (case sensitive)

Login Password

admin (case sensitive)

Serial Speed

9,600 bps

Serial Address

01

IP Address

192.168.1.1

Subnet Mask

255.255.255.0


Appendix B- General Information

DESCRIPTION

SPECIFICATION

Interconnect Cable

CAT 5/5e/6 Solid UTP EIA/TIA 568B wiring w/
male RJ45 connectors

"RS232" Connector

9D female

"ETHERNET" Connector

RJ45 female

"AV IN" and "AV OUT"
Connectors

RJ45 female

Operating temperature

+10

°

C to +40

°

C

Video quality adjustment

Automatic (up to 600 feet)

Replaceable fuse rating

2A 250V

Power requirements

110 or 220VAC, 50 or 60Hz, 1A




Appendix C- Distances and Resolutions for CAT5/CAT5e and CAT6 Cables

CABLE

DISTANCE (feet)

RESOLUTION

CAT5/CAT5e (UTP)

600

1024x768 at 60Hz

CAT5/CAT5e (UTP)

400

1280x1024 at 60Hz

CAT5/CAT5e (UTP)

300

1600x1200 at 60Hz

CAT5/CAT5e (UTP)

100

1920x1440 at 60Hz

CAT6 (UTP)

300

1024x768 at 60Hz

CAT6 (UTP)

200

1280x1024 at 60Hz

CAT6 (UTP)

100

1920x1440 at 60Hz




Appendix D- Product Dimensions

CONFIGURATION

SIZE (In.) WxDxH

SM-8X8-C5VA-LCD 19x12x1.75
SM-8X16-C5VA-LCD 19x12x1.75
SM-16X8-C5VA-LCD 19x12x1.75
SM-16X16-C5VA-LCD 19x12x3.5
SM-32X8-C5VA-LCD 19x12x3.5
SM-32X16-C5VA-LCD 19x12x3.5