6 after finishing work, 7 maintenance – Nilfisk-Advance America IVB 5-H User Manual

Page 12

Advertising
background image

10

english

IVB 3-H
IVB 5-H
IVB 7-H

6 After finishing work

6.1

Switching the vacuum
cleaner off and storage

1. After picking up hazardous

dust, vacuum clean the out-
side of the cleaner.

2. Switch off the vacuum clean-

er and pull the mains plug
out of the socket.

3. Remove the suction hose

form the vacuum cleaner and
close the inlet fitting (1) with
the plug (2).

4. Wind up the power cord and

hang it on the handle.

5. Empty the tank and clean the

vacuum cleaner.

6. After picking up liquids: Store

the upper section of the
cleaner separately so that
the filter element can dry.

7. Store the vacuum cleaner

in a dry room where it is
protected from unauthorized
use.

7 Maintenance

7.1 Maintenance

plan

After finishing work

As required

7.2.1

Replacing the waste bag

7.2.2

Replacing the safety filter bag

7.2.3

Replacing filter element „H“ (IVB 3-H)

7.2.4

Replacing filter element „H“ (IVB 5-H/7-H)

7.2.5

Emptying dirt tank (IVB 3-H/IVB 5-H)

7.2.6

Emptying dirt tank (IVB 7-H)

7.2 Maintenance

work

7.2.1 Replacing the waste

bag

IVB 3-H/IVB 5-H:
1. Open the retaining clamps

and remove the upper sec-
tion of the cleaner from the
dirt tank.

2. Carefully remove the waste

bag connection (1) from the
inlet fitting.

3. Close the waste bag connec-

tion with the slide (2).

4. Close the waste bag using

the cable binder (3).

Only after picking up harmless dust.

IVB 3-H

IVB 5-H

IVB 7-H

1

2

2

1

Advertising
This manual is related to the following products: