Configuration, Cascaded installation, Master unit (keemux-p4) – Network Technologies KEEMUX-Px User Manual

Page 10: Slave unit #2 (keemux-p4), Slave unit #1 (keemux-p4), Nti keemux series ps/2 kvm switch, Front panel configuration switches, Figure 6- cable connections for cascading

Advertising
background image

NTI KEEMUX Series PS/2 KVM Switch

6

Configuration

All 4, 8, and 16-port units are configured using the 8-position dip-switch (located on the front of each unit) according to tables 1
and 2 below.

Front Panel Configuration Switches

Table 1 * (default settings)

Switch

SW1

SW5

SW6

STAND-ALONE

SWITCH

OFF* OFF* OFF*

SLAVE ON

OFF

OFF

MASTER

W/4-PORT

SLAVES OFF OFF ON

MASTER

W/8-PORT

SLAVES OFF

ON OFF

MASTER

W/16-PORT

SLAVES

OFF

ON

ON

Table 2 * (default settings) Master & Slave SW2-4 Settings

SW2

SW3

SW4

Master with-

Slave Setting

OFF*

OFF*

OFF*

No Slave Attached

N/A

OFF

OFF

OFF

1 Slave attached

Slave Unit #1

OFF

OFF

ON

2 Slaves attached

Slave Unit #2

OFF

ON

OFF

3 Slaves attached

Slave Unit #3

OFF

ON

ON

4 Slaves attached

Slave Unit #4

ON

OFF

OFF

5 Slaves attached

Slave Unit #5

ON

OFF

ON

6 Slaves attached

Slave Unit #6

ON

ON

OFF

7 Slaves attached

Slave Unit #7

ON

ON

ON

8 Slaves attached

Slave Unit #8

Cascaded Installation

1. Attach all slaves consecutively to the master switch.

a. Perform steps 1 and 2 under INSTALLATION on page 4 for each slave unit.
b. Configure each switch as per the tables above under CONFIGURATION before proceeding.
c.

With a VEXT-xx-MM cable, connect slave #1 monitor port to master’s VIDEO 1 port.

d. With a VVKINT-xx-MM or (2) VKEXT-xx-MMs, connect slave #1’s PS/2 DEVICES ports to the
master’s CPU1 KEYBOARD and MOUSE ports.
e. Repeat steps c and d for each additional slave unit, keeping in mind that each slave will connect to the next available
master’s port (i.e. slave #2 to master’s VIDEO 2 and CPU 2 KEYBOARD and MOUSE, etc.). See Fig. 6 below.



































Figure 6- Cable connections for cascading


About Table 2:
These switch settings are used by the slave(s) to
establish its identity (i.e. location in the group) to
the master.

On a master, the same switches are used to
configure the master for how many slaves are
attached to it.

5VDC

2A

-

+

V

I

D

E

O
4

V

I

D

E

O
3

V

I

D

E

O
2

V

I

D

E

O

1

M

O

N

I

T

O

R

Mouse

CPU 1

C
P

U

1

C
P

U
2

C
P

U

3

C
P

U
4

CPU 2

CPU 3

CPU 4

Keyboard

Daisy Daisy
Out In

NTI

Tel:330-562-7070
Fax:330-562-1999

1275 Danner Dr
Aurora, OH 44202

www.nti1.com

R

PS/2 DEVICES

5VDC

2A

-

+

V

I

D

E

O
4

V

I

D

E

O
3

V

I

D

E

O

2

V

I

D

E

O

1

M

O

N

I

T

O

R

Mouse

CPU 1

C

P
U

1

C

P
U
2

C

P
U
3

C

P
U
4

CPU 2

CPU 3

CPU 4

Keyboard

Daisy Daisy
Out In

NTI

Tel:330-562-7070
Fax:330-562-1999

1275 Danner Dr
Aurora, OH 44202

www.nti1.com

R

PS/2 DEVICES

CPU 1

CPU 2

CPU 3

CPU 4

5VDC

2A

-

+

V

I

D

E

O
4

V

I

D

E

O
3

V

I

D

E

O

2

V

I

D

E

O

1

M

O

N

I

T

O

R

Mouse

CPU 1

C
P
U

1

C
P
U

2

C
P
U

3

C
P
U

4

CPU 2

CPU 3

CPU 4

Keyboard

Daisy Daisy
Out In

NTI

Tel:330-562-7070
Fax:330-562-1999

1275 Danner Dr
Aurora, OH 44202

www.nti1.com

R

PS/2 DEVICES

CPU 5

CPU 6

CPU 7

CPU 8

VVKINT-xx-MM

CPU 1-4

CPU 5-8

CONNECT SLAVES FOR CASCADED
CPU CONNECTIONS

MASTER UNIT (KEEMUX-P4)

If additional 4-PORT slaves are connected to
VIDEO, PS/2 MOU CPU, & PS/2 KBD CPU ports
3 & 4, they will function and be controlled as
CPU ports 9-12 and 13-16 respectively.
- OR-
If individual CPUs are connected
to ports 3 & 4, they will function and
be controlled as CPU ports 9 & 10
respectively.

SLAVE UNIT #2 (KEEMUX-P4)

For connection of CPUs 5-8

SLAVE UNIT #1 (KEEMUX-P4)

For connection of CPUs 1-4

VEXT-xx-MM

Advertising
This manual is related to the following products: