Unit Address and Loop Back

To allow multiple units to be controlled from a single CPU port, the RS232 control interface is designed to allow "daisy chaining"
up to 15 units. By setting the appropriate RS232 dip switches, each unit can be given a unique address (1-15). Then the unit will
only respond to commands on the bus if its address is embedded in the command. Use the table below to set the unit address.

DIP SWITCH

UNIT ADDRESS

8

7

6

5

OFF

OFF

OFF

OFF

0 (not valid)

OFF

OFF

OFF

ON

1

OFF OFF

ON OFF 2

OFF OFF

ON ON

3

OFF ON OFF OFF 4
OFF ON OFF ON 5
OFF ON ON OFF 6
OFF ON ON ON 7
ON OFF

OFF

OFF

8

ON OFF

OFF

ON 9

ON OFF

ON OFF

10

ON OFF

ON ON 11

ON ON

OFF

OFF

12

ON ON

OFF

ON 13

ON ON

ON OFF

14

ON ON

ON ON 15


Note: In order to connect multiple KEEMUX units together a Matrix-Y-1 cable must be used. (See Fig. 15.) See Fig. 16 for
the pinout of the Matrix-Y-1 cable. The Matrix-Y-1 cable is available from Network Technologies Inc.










Figure 15- RS232 connection with Matrix-Y-1 cable



















Figure 16- Pinout of Matrix-Y-1 cable

NTI

SWITCH

CPU

RS232

First Unit

NTI

SWITCH

RS232

NTI

SWITCH

RS232

Second Unit

Last Unit

RS232
Serial Port

Matrix-Y-1

Matrix-Y-1

Matrix-Y-1

(Unit #1)

(Source)

2

3

3

3

5

5

5

2

2

7
8

1
4
6

Jumper

Jumpers

Not connected to
source connector

(Unit #2)

9D Female

9D Male

9D Male

Wiring Schematic of Matrix-Y-1 cable

Advertising
This manual is related to the following products: