Chapter 1

Introduction

© National Instruments Corporation

1-7

R Series Intelligent DAQ User Manual

Note

If you use the R Series device without the FPGA Module, you can use the RIO

Device Setup utility, available by selecting Start»All Programs»National Instruments»
NI-RIO»RIO Device Setup
to download precomplied FPGA VIs to the flash memory of
the R Series device. This utility is installed by the NI-RIO CD. You also can use the utility
to configure the analog input mode, to synchronize the clock on the R Series device to the
PXI clock (for NI PXI-78xxR only), and to configure when the VI loads from flash
memory. For more information about using the RIO Device Setup utility, refer to the RIO
Device Setup Help
, found at Start»All Programs»National Instruments»NI-RIO»RIO
Device Setup Help
.

LabVIEW Real-Time Module

The LabVIEW Real-Time Module extends the LabVIEW development
environment to deliver deterministic, real-time performance.

You can write host VIs that run in Windows or on RT targets to
communicate with FPGA VIs that run on the NI 78xxR. You can develop
real-time VIs with LabVIEW and the LabVIEW Real-Time Module, and
then download the VIs to run on a hardware target with a real-time
operating system. The LabVIEW Real-Time Module allows you to use the
NI 78xxR in RT Series PXI systems being controlled in real time by a VI.

The NI 781xR is designed as a single-point DIO complement to the
LabVIEW Real-Time Module. The NI 783xR/784xR/785xR is designed as
a single-point AI, AO, and DIO complement to the LabVIEW Real-Time
Module. Refer to the LabVIEW Help, available by selecting Help»Search
the LabVIEW Help
, for more information about the LabVIEW
Real-Time Module.