Summary of maintenance controls (petrol version) – Nilfisk-Advance America SR 5120 P/B User Manual

Page 26

Advertising
background image

S31NUK5120(3)2001-04

Warning: the following interventions must be done with machine in Off condition and master key

out. All the periodic maintenance operations must be performed by skilled personnel or
by an authorized service centre.

Every maintenance intervention on the petrol engine must be performed in agreement with the
engine User Manual.

Note: the battery life will depend on a good periodic maintenance (check of the level of the

electrolyte and of battery voltage). Besides it must be taken into account that an unused
battery is submitted to a self-discharge phenomenon. In the event that the machine is not
used for a long time (e.g. 3 or 4 weeks) it is necessary TO RECHARGE THE BATTERY;
infact the battery voltage MUST NEVER drop down below 20 Volt.

SUMMARY OF MAINTENANCE
CONTROLS (petrol version)

24

For SR1100: 3200 engine shaft RPM with no function working and battery voltage higher than 27
Volt
For SR 1200: 3300 engine shaft RPM with no function working and battery voltage higher than 27
Volt
(+) 20 hours or not more than 1 month
(++) 100 hours or not more than 8 months

CONTROL

UPON

DELIVERY

TWO

TIMES PER

WEEK

ONE

TIME PER

WEEK

EVERY

20

HOURS

EVERY

50

HOURS

EVERY

100

HOURS

EVERY

400

HOURS

Battery liquid level and voltage
check

Engine air filter cleaning

Panel filter cleaning

Engine oil level check

1

st

TIME

Engine oil replacement

(+)

1

st

TIME

(++)

Engine RPM check and
adjustment (*)

Check the carbon brushes of all
electrical motors and replace
them if worn

Belt tension

Brake adjustment

Filter shaker

Nut and screw tightness

Wear of main brush and side
brushes

Sealing of gaskets of filter
compartment and of flaps

Clean the steering chain and
(SR 1200 - SR 5120 only) the
traction wheels chains with gas-
oil or a proper solvent.

Advertising