Environmental – National Instruments NI 9233 User Manual

Page 29

Advertising
background image

© National Instruments Corp.

29

NI 9233 Operating Instructions and Specifications

Operating shock
(IEC 60068-2-27).............................. 30 g, 11 ms half sine,

50 g, 3 ms half sine,
18 shocks at 6 orientations

Environmental

National Instruments C Series modules are intended for indoor use
only but may be used outdoors if installed in a suitable enclosure.
Refer to the manual for the chassis you are using for more
information about meeting these specifications.

Operating temperature
(IEC 60068-2-1, IEC 60068-2-2) ..... –40 to 70 °C

Storage temperature
(IEC 60068-2-1, IEC 60068-2-2) ..... –40 to 85 °C

Ingress protection.............................. IP 40

Operating humidity
(IEC 60068-2-56).............................. 10 to 90% RH,

noncondensing

Storage humidity
(IEC 60068-2-56).............................. 5 to 95% RH,

noncondensing