Network add/drop ring application, Figure 3, Cwdm oadm network and equipment side connections – Nortel Networks 10292FA User Manual

Page 20: Figure 4, Cwdm oadm front panel

Advertising
background image

20

Chapter 1 Describing the optical routing system

212257-B

Figure 3 CWDM OADM network and equipment side connections

The CWDM OADM (

Figure 4

) is installed in a 19-inch, rack-mounted 1RU

optical shelf (

Figure 15

).

Figure 4 CWDM OADM Front Panel

For information about installing a CWDM OADM, see

“Inserting a CWDM

OADM or a CWDM OMUX” on page 38

. For specifications, see

“CWDM

OADM specifications” on page 45

.

Network add/drop ring application

The CWDM OADM pulls off a specific wavelength from an optical ring and
passes it to a CWDM GBIC of the same wavelength in the switch, leaving all
other wavelengths on the ring undisturbed. CWDM OADMs are set to one of
eight supported wavelengths (

Table 1

).

Note:

The wavelength of the CWDM OADM and the corresponding

CWDM GBIC must match (see

Table 1

).

To CWDM GBIC

To

N

e

tw

o

rk

To
N
e

tw

o

rk

TX

TX

RX

RX

TX

RX

Equipment side

To CWDM GBIC

TX

RX

Single-wavelength OADM