Cabling an eight-channel cwdm omux – Nortel Networks 10292FA User Manual

Page 42

Advertising
background image

42

Chapter 3 Installing the shelf, OADM, and OMUX

212257-B

4

Make the following network backbone connections (

Figure 17

):

Connect the network backbone east fiber optic cables to the east (left)
CWDM OMUX-4.

Connect the network backbone west fiber optic cables to the west (right)
CWDM OMUX-4.

Cabling an eight-channel CWDM OMUX

This section describes how to cable the following:

CWDM GBIC to a CWDM OMUX-8 (

Figure 18

)

CWDM OMUX-8 to network backbone interfaces (

Figure 18

)

To connect a CWDM OMUX-8:

1

Install the CWDM GBICs (wavelength specific) into the network device(s).
To install a CWDM GBIC, see Installing CWDM Gigabit Interface
Converters,
part number 212256-B.

2

Clean all fiber optic connectors on the cabling (see

“Handling and cleaning

fiber optic equipment” on page 49

).

3

Connect the fiber optic cables from the CWDM GBIC TX and RX connectors
to the CWDM OMUX-8 RX and TX connectors (

Figure 18

).

Note:

The CWDM GBIC wavelength must match the CWDM OMUX-4

equipment connector wavelength.

The TX of one device must always connect to the RX of the next device.

Note:

The CWDM OMUX-8 located on the left side of the chassis

terminates the east network backbone connection. The CWDM OMUX-8
on the right side of the chassis terminates the west network backbone
connection. See

Figure 18

.

Note:

The wavelength of the CWDM GBIC must match the wavelength

of the CWDM OMUX-8 equipment connector.