Table 7, Hub and spoke signal loss values, Table 8 – Nortel Networks 10292FA User Manual

Page 34

Advertising
background image

34

Chapter 2 Calculating transmission distance

212257-B

Table 7

shows typical loss values that can be used to calculate the transmission

distance for the hub and spoke network in

Figure 13

.

Table 8

shows the calculations used to determine maximum transmission distance

for the hub and spoke network in

Figure 13

.

Transmission distance calculation for the hub and spoke network example in

Figure 13

:

Table 7 Hub and spoke signal loss values

Signal loss element

value

Loss budget

30 dB

CWDM OADM insertion add loss

1.9 dB

CWDM OADM passthrough loss

2.0 dB

CWDM OMUX8 demux loss

4.5 dB

System margin

3 dB

Fiber attenuation

.25 dB per km

Table 8 Hub and spoke maximum transmission distance calculations

Result

Calculation

Passthrough nodes

Passive loss

Implied fiber loss

Maximum transmission
distance

the number of OADMs between add OADM and OMUX

OADM add

OMUX8 demux

passthrough nodes

OADM passthrough loss

×

(

)

+

+

loss budget

passive loss

system margin

implied fiber loss

attenuation per kilometer

÷

7 Passthrough nodes
1.9 dB

4.5 dB

+

7

2.0

×

(

)

20.4 dB Passive Loss

=

+

30 dB 20.4 dB

3 dB

6.6 dB Implied Fiber Loss

=

6.6 dB

.25 dB

26.4 km Maximum Transmission Distance

=