NI 9425 Operating Instructions and Specifications

12

ni.com

I/O protection

Input voltage

8 channels ............................ 60 VDC max
32 channels .......................... 30 VDC max

Reverse-biased voltage

8 channels ............................ –60 VDC max
32 channels .......................... –30 VDC max

Hold time

1

......................................... 0

μs min

Setup time

2

........................................ 1

μs min

Update/transfer time

3

cRIO-9151 R Series
Expansion chassis....................... 8

μs max

All other chassis ......................... 7

μs max

1

Hold time is the amount of time input signals must be stable after initiating a read
from the module.

2

Setup time is the amount of time input signals must be stable before reading from the

module.

3

The update/transfer time is valid when the module is used in a CompactRIO system.

When used in other systems, driver software and system latencies impact this time.