Specifications, Electrical, Mechanical – National Instruments SCXI-1321 User Manual

Page 6: Maximum working voltage

Advertising
background image

SCXI-1321 Terminal Block Installation Guide

6

ni.com

Note

To minimize the temperature gradient inside the terminal block, move the SCXI

chassis away from any extreme temperature differential.

Specifications

All specifications are typical at 25 °C unless otherwise specified.

Electrical

Cold-junction sensor

Accuracy

1

........................................0.9 °C

Output ..............................................10 mV/°C from 0 to 55 °C

Resistors

R

SHUNT

.............................................301 k

Ω ±1%

R

NULL

...............................................39 k

Ω ±5%

R

TRIM

...............................................10 k

Nulling potentiometer

Range...............................................0 to 10 k

Step size...........................................infinite (user adjustable)

Mechanical

Resistor sockets

Connecting lead size........................0.023 to 0.026 in.

Connecting lead length ....................0.110 to 0.175 in.

Lead spacing....................................0.500 in.

Maximum Working Voltage

Maximum working voltage refers to the signal voltage plus the
common-mode voltage.

Channel-to-earth .....................................300 V, Installation Category II

Channel-to-channel.................................300 V, Installation Category II

1

The temperature sensor accuracy includes tolerances in all component values caused by temperature and loading,
and self-heating.

Advertising