N-Tron Industrial Ethernet Switch 900 User Manual

Page 9

Advertising
background image

Rev050908

9

902FX/FXE & 904FX /FXE HALF DUPLEX SETUP

All 900 series fiber modules are factory configured for full duplex operation. The setting is controlled
by jumper JP1 on the backplane.
Note: Most 100Mbit fiber systems will be compatible with this Full Duplex setting. If Half Duplex
operation is desired, then follow these steps using proper wrist strap grounding techniques:

1. Remove the power & power plugs from the unit.
2. Loosen all thumbscrews & remove all modules.
3. Remove the six screws holding the backplane
4. Remove the backplane.
5. Move the jumper JP1 from position 1-2 to 3-4
6. Re-install the backplane & modules & power plugs.




902/904 Note:

Rev. C & D boards are hard wired for Port1 = HDPLX,
Rev. B & E boards are hard wired for Port1 = FDPLX.

JP1