Chapter 2

Installation and Configuration

NI PXI-1052 User Manual

2-20

ni.com

You can use the Inhibit signal (active low) to power off the chassis. To
remotely power off the chassis, connect the Inhibit pin (pin 5) to a Logic
Ground pin (pins 1 or 9). As long as this connection exists, the chassis
remains off (standby). When you remove this connection, the chassis
powers on.

Note

For the Inhibit signal to control the On/Off (Standby) state of the chassis, the front

power switch must be in the On (recessed) position.

Table 2-1. Remote Inhibit and Voltage Monitoring Connector Pinout

D-Sub Pin

Signal

1

Logic Ground

2

+5 VDC

3

Reserved

4

+3.3 VDC

5

Inhibit (Active Low)

6

+12 VDC

7

Reserved

8

–12 VDC

9

Logic Ground

1

2

3

4

5

6

9

7

8