Dc output – National Instruments PXI NI PXI-1052 User Manual

Page 42

Advertising
background image

Appendix A

Specifications

NI PXI-1052 User Manual

A-2

ni.com

Power disconnect ....................................The AC power cable provides

main power disconnect.
Depressing the front-panel power
switch controls the internal
chassis power supply that
provides DC power to the
CompactPCI/PXI backplane. You
also can use the rear-panel 9-pin
D-Sub connector to control the
internal chassis power supply.

DC Output

DC current capacity (I

MP

)

Maximum ripple and noise (20 MHz bandwidth)

Voltage

0–50 °C

50–55 °C

+3.3 V

12 A

12 A

+5 V

17 A

17 A

+12 V

2 A

2 A

–12 V

1 A

1 A

+20 V

1.36 A

1.16 A

–20 V

1.36 A

1.16 A

Voltage

Maximum Ripple and Noise

+3.3 V

50 mV

pp

+12 V

120 mV

pp

+5 V

50 mV

pp

–12 V

120 mV

pp

+20 V

200 mV

pp

–20 V

200 mV

pp

Advertising