Interactive control syntax, Number syntax, Interactive control syntax -4 – National Instruments NI-488.2 User Manual

Page 64: Number syntax -4

Advertising
background image

Chapter 7

Interactive Control Utility

NI-488.2 User Manual

7-4

ni.com

Or, equivalently:

ud0:

ibrd 29

[0100] (cmpl)

count: 29

46 4C 55 4B 45 2C 20 34

FLUKE, 4

35 2C 20 34 37 39 30 31

5, 47901

37 33 2C 20 31 2E 36 20

73, 1.6

44 31 2E 30 0A

D.10.

5.

When you finish communicating with the device, make sure you put
it offline using the

ibonl

command, as follows:

ud0:

ibonl 0

[0100] (cmpl)

:

The

ibonl

command properly closes the device handle and the

ud0

prompt is no longer available.

6.

To exit Interactive Control, type

q

.

Interactive Control Syntax

The following special rules apply to making calls from the Interactive
Control utility:

The

ud

or

BoardId

parameter is implied by the Interactive Control

prompt; therefore it is never included in the call.

Except for reads, the

count

parameter to calls is unnecessary because

buffer lengths are automatically determined by Interactive Control.

Function return values are handled automatically by Interactive
Control. In addition to printing out the return

ibsta

value for the

function, it also prints other return values.

If you do not know what parameters are appropriate to pass to a
given function call, type in the function name and press <Enter>.
The Interactive Control utility then prompts you for each
required parameter.

Number Syntax

You can enter numbers in either hexadecimal or decimal format.

Hexadecimal numbers—You must prefix hexadecimal numbers with

0x

.

For example,

ibpad 0x16

sets the primary address to 16 hexadecimal

(22 decimal).