Status Word Conditions

This appendix gives a detailed description of the conditions reported in the
status word,

ibsta

.

For information about how to use

ibsta

in your application program, refer

to the NI-488.2 online help. For instructions on accessing the online help,
refer to the

Using the NI-488.2 Documentation

section in

About This

Manual

.

Each bit in

ibsta

can be set for device calls (dev), board calls (brd),

or both (dev, brd). Table B-1 shows the status word layout.

Table B-1. Status Word Layout

Mnemonic

Bit Pos

Hex Value

Type

Description

ERR

15

8000

dev, brd

NI-488.2 error

TIMO

14

4000

dev, brd

Time limit exceeded

END

13

2000

dev, brd

END or EOS detected

SRQI

12

1000

brd

SRQ interrupt received

RQS

11

800

dev

Device requesting service

CMPL

8

100

dev, brd

I/O completed

LOK

7

80

brd

Lockout State

REM

6

40

brd

Remote State

CIC

5

20

brd

Controller-In-Charge

ATN

4

10

brd

Attention is asserted

TACS

3

8

brd

Talker

LACS

2

4

brd

Listener

DTAS

1

2

brd

Device Trigger State

DCAS

0

1

brd

Device Clear State