Rackmounting instructions – Network Technologies DVI-x User Manual

Page 7

Advertising
background image

NTI UNIMUX SERIES USB KVM SWITCH

4


RACKMOUNTING INSTRUCTIONS

This NTI switch was designed to be mounted to a rack or to set on a desktop. It includes rackmount ears to make attachment to
a rack easy, and rubber feet to be applied to the bottom of the case if it will instead sit on a flat surface. If this will sit on a flat
surface, simply apply the rubber feet to the bottom of the case in each of the 4 corners.

To Mount to a Rack


1. Attach the ears to the switch using the 6-32x3/16" flat Phillips-head screws (6) provided as shown in the illustration below.
The holes in the ears should line up with pre-threaded holes in the sides of the NTI switch. Tighten the screws securely.



















Figure 1- Secure rackmount ears to switch


2. Install 4 captive nuts (not supplied) to the rack in locations that line up with the holes in the mounting ear on the NTI switch.

3. Secure the NTI switch to the rack using four rack screws (10-32, 12-24, M6, etc.- not supplied). Each screw should be of
sufficient length to go completely through the NTI mounting ear, rack frame and fully engage all threads in the captive nut.
Be sure to tighten all mounting screws securely.

4. Attach all cables securely to the switch and where necessary supply adequate means of strain relief for cables.






















Figure 2- Secure switch to a rack


6-32x3/16"

Flat Head

Screws

(Provided)

Rackmount Ear

NTI Switch

Front of Switch

Cage Nuts

Rack Screws

Rack

(not supplied)

(not supplied)

NTI Switch

Advertising
This manual is related to the following products: