Appendix A

Specifications

NI ExpressCard MXI Series User Manual

A-4

ni.com

Environment

1

Maximum altitude...................................2,000 m (800 mbars)

(at 25 °C ambient temperature)

Pollution Degree .....................................2

Indoor use only

Operating Environment

Ambient temperature range ....................0 to 55 °C

(Tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2. Meets
MIL-PRF-28800F Class 3 low
temperature limit and
MIL-PRF-28800F Class 2 high
temperature limit.)

Relative humidity range..........................10 to 90%, noncondensing

(Tested in accordance with
IEC-60068-2-56.)

Storage Environment

Ambient temperature range ....................–40 to 71 °C

(Tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2. Meets
MIL-PRF-28800F Class 3 limits.)

Relative humidity range..........................5 to 95%, noncondensing

(Tested in accordance with
IEC-60068-2-56.)

Shock and Vibration

Operational shock ...................................30 g peak, half-sine, 11 ms pulse

(Tested in accordance with
IEC-60068-2-27. Meets
MIL-PRF-28800F Class 2 limits.)

1

Specifications are subject to change without notice.