1.1.8 Configuring the cleaning trigger 2 (Clean Trg. 2) (MHTC Reflow only)


Note: The cleaning trigger 2 to configure operation dependent draining appears
only with the MHTC Reflow. With the cleaning trigger 2 settings you determine
whether operation dependent draining is triggered depending on the fill cycles or
on the conductivity of the water in the water tub (option) or whether the cleaning
trigger 2 should be deactivated.

Select “Clean Trg. 2” in the settings menu, then
press the <Set> key. The current settings for
the operation dependent draining appear. The
settings available depend on whether the
operation dependent draining is deactivated
(Off, factory setting) or the fill cycle (Cycle) or
the conductivity controlled (µ Sensor) triggering
of the operation dependent draining is selected.

Operation dependent draining deactivated (Off)

Fill cycle controlled draining (Cycle). With the
parameter “Cycle” you can determine after how
many filling cycles a drain is performed (setting
range: 10...10000, factory setting: 100).

Conductivity controlled draining (µ Sensor)
(Requires optional components). With the
parameter “µS Limit” you can set a conductivity
limit value. If during operation the conductivity
value of the water in the tub reaches the set
limit, a draining is performed (setting range:
10...5 000 µS, factory setting: 1000µS).