Reference guide – North Star 8000 IPG User Manual
Page 9
Machine Component Identification - Item #165920S
9
REFERENCE GUIDE
Reference 1 – Air Cleaner
Refer to your Honda engine manual for air cleaner care.
Reference 2 – Oil Drain Plug
Refer to your Honda engine manual for oil change
recommendations.
Reference 3 – Full Power Switch
The switch reconnects the two generator windings from
parallel (120V only) to series (120/240V).
• 120V Only: Allows all 6600 watts (55A) to be used in
any combination of 120 volt receptacles. The 120/240V
30A locking device receptacle is 120V only at this time.
• 120/240V : Allows all 6600 watts to be used for 240V.
However, only half the power or 3300 watts (27.5A), can
be used at any one 120V receptacle. 120V output can
total 6600 watts.
Reference 4 – Voltmeter
Voltmeter needle should be in green area during all generator
load conditions.
Reference 5 – Idle Control On/Off
Switch
This feature senses the load on the generator. With no load
on the generator the engine speed drops to idle. This saves
fuel and lengthens engine life. When a load is applied, the
engine speed returns to 3600 - 3780 RPMs. Turning the
switch off disables the sensing device and the generator will
run at 3600 - 3750 RPM whether or not a load is applied.
Note: When the engine is idling, it is normal for the
voltmeter needle to be in the red range.
Reference 6 – Hour Meter
Allows for better maintenance scheduling of generator.
Reference 7 – Main Line Circuit
Breaker 30A
30 amp (A) magnetic 2-pole main circuit breaker to protect
against electrical overloads.
Reference 8 – 50A Circuit Breaker
50 amp (A) push-to-reset circuit breaker
Reference 9 – 30A Circuit Breaker
30 amp (A) push-to-reset circuit breaker
Reference 10 – 20A Circuit Breaker
20 amp (A) push-to-reset circuit breaker
Reference 11 – Gas Cap with
Gauge
The gas cap is extra large, creating a large hole for
refueling. You can monitor the fuel level without removing
the cap by using the fuel level indicator built into the gas
cap.
Reference 12 – 6.5 Gallon Gas Tank
Large tank allows for extended run capabilities. ALWAYS
allow room for gasoline expansion by not filling the gas tank
completely full.
Reference 13 – Super Silent Muffler
4 dB less than Honda’s standard muffler.
Reference 14 – Generator Head
The electricity producing part of the generator.
Reference 15 – Battery Box
The battery box provides protection for the battery and will
accept a standard lawn tractor size battery (Group U1-7).
The engine requires a 12-volts battery, with a minimum
rating of 18Ah (Amp-Hour). See battery section for sizing.
Reference 16 – Vibration Isolation
Mount
The engine and generator are mounted on rubber cylinders
that absorb most of the engine vibration. This feature
eliminates the tendency of the machine to “walk” which is
common in engine powered equipment.
Reference 17 – Recoil
Grasp firmly when starting engine. Consult engine manual
for further instruction.
Reference 18 – Fuel Shut-Off Valve
The engine is equipped with an ON-OFF valve located on
the left side of the recoil. ALWAYS keep this valve closed
when the generator is not in use.
Reference 19 – Choke Lever
Used during cold starts. Refer to the starting/stopping
instructions and the Honda engine manual for usage.
Reference 20 – Engine Starting Key The engine key is located on the engine. Always locate this
switch and be familiar with its location before operating the
generator.