Raid 0+1 (mirroring+striping) – Rosewill RC212 User Manual

Page 10

Advertising
background image


SATA+ULTRA ATA RAID CONTROLLER

RC212 User Manual


10

you that build is finished. Rebuild Mirror Drive

12.

When a failure to one member occurs, you will be notified by the RAID BIOS during

boot. The steps below will guide you in rebuilding a failed mirror set.

13.

Replace he failed drive(s) with one of equal or greater capacity, then start the computer.

14.

Then you will see the following message shown by the PCI SATA+PATA RAID card’s

BIOS on the screen.

Power off and check the failed drive

Destory the Mirroring Relationship

Choose replacement drive and rebuild

Continue to boot

15.

Select Choose replacement drive and rebuild, press Enter.

16.

Select the replacement drive then press Enter.

17.

When asked WARNING: Would you like to Continue? Press Y/N?, press Y to accept.

18.

The set will be rebuilt. The status of the rebuild is displayed in the menu.

19.

When rebuild is completed, a Enter the VIA RAID Utility after exiting?(Y/N)

message will pop up inform you that rebuild is finished, press N to reboot system.

RAID 0+1 (Mirroring+Striping)

This RAID array to be used on New/Blank hard drives, do not use existing hard drive(s)

with data. To create a RAID 0+1 set four hard drives are required.

Auto configuration (recommended)

The default chunk size is 64k when selecting Auto configuration.