Parameter
Value (Dec.)
Value (Hex.) min - max MSB/LSB(H)
46 : Cho
→
Flanger
02
0B
Cho Dly
0 - 1.0m - 100m
*1
03
Cho Rate
0.05 - 0.45 - 10.0
*6
04
Cho Depth
0 - 120 - 127
00 - 7F
05
+ Cho Bal
D> 0E - D=E - D 0<E
00 - 7F
07
FL Dly
0 - 1.6m - 100m
*1
08
FL Rate
0.05 - 0.60 - 10.0
*6
09
FL Depth
0 - 24 - 127
00 - 7F
0A
FL Fb
-98% - +80% - +98%
0F - 71
0B
# FL Bal
D> 0E - D=E - D 0<E
00 - 7F
0C
Low Gain
-12 - 0 - +12
34 - 4C
13
Hi Gain
-12 - 0 - +12
34 - 4C
14
Level
0 - 112 - 127
00 - 7F
16
❍
Effects that connect three or more types of
effect in series (series 3 / series 4 / series 5)
47 : Rotary Multi
02
0C
+ OD Drive
0 - 13 - 127
00 - 7F
03
OD Sw
Off/On
00/01
04
EQ L Gain
-12 - 0 - +12
34 - 4C
05
EQ M Fq
200 - 1.6k - 6.3k
*10
06
EQ M Q
0.5/1.0/2.0/4.0/9.0
00/01/02/03/04
07
EQ M Gain
-12 - 0 - +12
34 - 4C
08
EQ H Gain
-12 - 0 - +12
34 - 4C
09
RT L Slow
0.05 - 0.35 - 10.0
*6
0A
RT L Fast
0.05 - 6.40 - 10.0
*6
0B
RT Lo Accl
0 - 3 - 15
*14
0C
RT Lo Lev
0 - 127
00 - 7F
0D
RT H Slow
0.05 - 0.90 - 10.0
*6
0E
RT H Fast
0.05 - 7.50 - 10.0
*6
0F
RT Hi Accl
0 - 11 - 15
*14
10
RT Hi Lev
0 - 64 - 127
00 - 7F
11
RT Sept
0 - 96 - 127
00 - 7F
12
# RT Speed
Slow/Fast
00/7F
13
Level
0 - 96 - 127
00 - 7F
16
48 : GTR Multi 1
04
00
Cmp Atck
0 - 100 - 127
00 - 7F
03
Cmp Sus
0 - 80 - 127
00 - 7F
04
Cmp Level
0 - 100 - 127
00 - 7F
05
Cmp Sw
Off/On
00/01
06
OD Sel
Odrv/Dist
00/01
07
+ OD Drive
0 - 80 - 127
00 - 7F
08
OD Amp
Small/BltIn/2-Stk/3-Stk
00/01/02/03
09
OD Amp Sw
Off/On
00/01
0A
OD L Gain
-12 - +5 - +12
34 - 4C
0B
OD H Gain
-12 - +10 - +12
34 - 4C
0C
OD Sw
Off/On
00/01
0D
CF Sel
Chorus/Flangr
00/01
0E
CF Rate
0.05 - 0.45 - 6.40
*7
0F
CF Depth
0 - 30 - 127
00 - 7F
10
CF Fb
-98% - +76% - +98%
0F - 71
11
CF Mix
0 - 40 - 127
00 - 7F
12
Dly Time
0m - 300m - 635m
*5
13
Dly Fb
0 - 34 - 127
00 - 7F
14
# Dly Mix
0 - 15 - 127
00 - 7F
15
Level
0 - 110 - 127
00 - 7F
16
49 : GTR Multi 2
04
01
Cmp Atck
0 - 70 - 127
00 - 7F
03
Cmp Sus
0 - 127
00 - 7F
04
Cmp Level
0 - 90 - 127
00 - 7F
05
Cmp Sw
Off/On
00/01
06
Parameter
Value (Dec.)
Value (Hex.) min - max MSB/LSB(H)
OD Sel
Odrv/Dist
00/01
07
+ OD Drive
0 - 80 - 127
00 - 7F
08
OD Amp
Small/BltIn/2-Stk/3-Stk
00/01/02/03
09
OD Amp Sw
Off/On
00/01
0A
OD Sw
Off/On
00/01
0B
EQ L Gain
-12 - +12
34 - 4C
0C
EQ M Fq
200 - 1k - 6.3k
*10
0D
EQ M Q
0.5/1.0/2.0/4.0/9.0
00/01/02/03/04
0E
EQ M Gain
-12 - +5 - +12
34 - 4C
0F
EQ H Gain
-12 - -10 - +12
34 - 4C
10
CF Sel
Chorus/Flangr
00/01
11
CF Rate
0.05 - 0.45 - 6.40
*7
12
CF Depth
0 - 96 - 127
00 - 7F
13
CF Fb
-98% - +76% - +98%
0F - 71
14
# CF Mix
0 - 127
00 - 7F
15
Level
0 - 80 - 127
00 - 7F
16
50 : GTR Multi 3
04
02
Wah Fil
LPF/BPF
00/01
03
+ Wah Man
0 - 60 - 127
00 - 7F
04
Wah Peak
0 - 10 - 127
00 - 7F
05
Wah Sw
Off/On
00/01
06
OD Sel
Odrv/Dist
00/01
07
# OD Drive
0 - 80 - 127
00 - 7F
08
OD Amp
Small/BltIn/2-Stk/3-Stk
00/01/02/03
09
OD Amp Sw
Off/On
00/01
0A
OD L Gain
-12 - 0 - +12
34 - 4C
0B
OD H Gain
-12 - 0 - +12
34 - 4C
0C
OD Sw
Off/On
00/01
0D
CF Sel
Chorus/Flangr
00/01
0E
CF Rate
0.05 - 0.45 - 6.40
*7
0F
CF Depth
0 - 127
00 - 7F
10
CF Fb
-98% - +50% - +98%
0F - 71
11
CF Mix
0 - 50 - 127
00 - 7F
12
Dly Time
0m - 160m - 635m
*5
13
Dly Fb
0 - 64 - 127
00 - 7F
14
Dly Mix
0 - 30 - 127
00 - 7F
15
Level
0 - 88 - 127
00 - 7F
16
51 : Clean Gt Multi1
04
03
Cmp Atck
0 - 50 - 127
00 - 7F
03
Cmp Sus
0 - 127
00 - 7F
04
Cmp Level
0 - 75 - 127
00 - 7F
05
Cmp Sw
Off/On
00/01
06
EQ L Gain
-12 - +12
34 - 4C
07
EQ M Fq
200 - 6.3k
*10
08
EQ M Q
0.5/1.0/2.0/4.0/9.0
00/01/02/03/04
09
EQ M Gain
-12 - +5 - +12
34 - 4C
0A
EQ H Gain
-12 - +12
34 - 4C
0B
CF Sel
Chorus/Flangr
00/01
0C
CF Rate
0.05 - 0.45 - 6.40
*7
0D
CF Depth
0 - 40 - 127
00 - 7F
0E
CF Fb
-98% - +30% - +98%
0F - 71
0F
+ CF Mix
0 - 100 - 127
00 - 7F
10
Dly Time
0m - 120m - 635m
*5
11
Dly Fb
0 - 40 - 127
00 - 7F
12
Dly HF
315 - 8k/Bypass
*8
13
# Dly Mix
0 - 30 - 127
00 - 7F
14
Level
0 - 95 - 127
00 - 7F
16
+: Effect control 1 can be used to modify the value (p.92)
#: Effect control 2 can be used to modify the value (p.92)
MSB/LSB: Indicates the ** portion of the following exclusive
messages. (p.196) (hexadecimal notation)
For Effect Type (data section)
F0 41 dev 42 12 40 03 00 ** ** sum F7
For Effect Parameters (LSB part of address)
F0 41 dev 42 12 40 03 ** data sum F7
(dev: device ID, sum: checksum)
The correspondence between setting values and hexadeci-
mal values for items in the Value column indicated with "*" is
shown in the "Effect Data Table" (p. 183).
*1
Pre Delay Time
*8
HF Damp
*2
Delay Time 1
*9
Cutoff Freq
*3
Delay Time 2
*10
EQ Freq
*4
Delay Time 3
*11
LPF
*5
Delay Time 4
*12
Manual
*6
Rate 1
*13
Azimuth
*7
Rate 2
*14
Accl