Installation, Important: save these instructions, For your safety – Regency E33-NG User Manual

Page 5: Gas pressure testing, Specifications, Before you start

Advertising
background image

5

E33 FPI Direct Vent Gas Insert

IMPORTANT:

SAVE THESE

INSTRUCTIONS

The FPI Gas Fireplace must be installed in
accordance with these instructions. Carefully
read all the instructions in this manual fi rst.
Consult the building authority having jurisdic-
tion to determine the need for a permit prior to
starting the installation.

NOTE: Failure to follow the instructions could
cause a malfunction of the heater which could
result in death, serious bodily injury, and/or
property damage. Failure to follow these
instructions may also void your fi re insurance
and/or warranty.

FOR YOUR SAFETY

This appliance requires air for proper combus-
tion. Always provide adequate combustion and
ventilation air. Follow instructions and informa-
tion in CSA B149.1 (in Canada) or the National
Fuel Gas Code ANS Z223.1/NFPA (in the USA),
regarding requirements for combustion and
ventilation air.

GAS PRESSURE

TESTING

The appliance must be isolated from the gas
supply piping system by closing its individual
manual shut off valve during any pressure
testing of the gas supply piping system at test
pressures equal to or less than
1/2 psig. (3.45 kPa).

SPECIFICATIONS

At pressures over 1/2 psig, the pipe to the unit
must be disconnected.
Gas Input Capacity:
Natural

Gas

38,000

Btu/h

Propane

35,500

Btu/h

Min. Input:
Natural

Gas

20,000

Btu/h

Propane

19,000

Btu/h

Fuels: Approved for use with both natural gas,
and propane. Approved as is for use at 0' to
4,500' (0-1370m).
Electrical: 120V A.C. system.
Circulation Fan: Variable speed, 127 CFM.
Log Set: Ceramic fi bre, 8 per set.
Vent System: 3" co-linear aluminum fl ex.

INSTALLATION

INSTALLATION INTO A

SOLID FUEL BURNING

FIREPLACE OR

FACTORY BUILT

FIREPLACE

The E33 Gas Inserts have been tested and ap-
proved to be vented into any masonry fi replace
or approved solid fuel burning factory built
fi replace that will allow the insert to physically
fi t into the fi rebox. Refer to page 6 for minimum
fi replace clearances.

If the factory built fi replace* height is too low
for your Insert, you may remove the smoke
baffl e plate and damper from the factory
built fi replace as long as these items are
saved and are reinstalled in the event that
the Insert is removed. NOTE: Any alterations
made to the listed solid fuel burning factory
built fi replace may void the listing of the
fi replace. Cutting any sheet-metal parts of
the fi replace, in which the gas fi replace insert
is to be installed, is prohibited.

If the factory-built fi replace has no gas ac-
cess hole(s) provided, an access hole of
1.5" (37.5mm) or less may be drilled through
the lower sides or bottom of the fi rebox in
a proper workmanship like manner. This
access hole must be plugged with non-com-
bustible insulation after the gas supply line
has been installed.

The fi replace and fi replace chimney must be
clean and in good working order and con-
structed of non-combustible materials and
chimney cleanouts must fi t properly. Refrac-
tory, glass doors, screen rails, screen mesh,
and log grates can be removed from the
fi replace before installing the gas fi replace
insert. Smoke shelves, shields and baffl es
may be removed if attached by mechani-
cal fasteners. A tight connection between
the gas fi replace insert fl ue collar and the
fi replace chimney must be made.

*Check with your local inspector before com-
mencing with this installation.

BEFORE YOU START

Safe installation and operation of this appliance
requires common sense, however, we are
required by the Canadian Safety Standards
and ANSI Standards to make you aware of
the following:

General Safety Information

1) The appliance installation must conform

with local codes or in the absence of local
codes, with CAN/CSA B149.1 (in Canada)
or the National Fuel Gas Code ANSI Z223.1
NFPA 54 in the U.S.A. This appliance should
be installed by a qualifi ed gas fi tter technician
only.

2) Installation and repair should be done

by a qualifi ed service person.

3) The appliance should be inspected

before use and at least annually by a
professional service person. More fre-
quent cleaning may be required due to
excessive lint from carpeting, bedding
material, animal hair, etc. It is impera-
tive that control compartments, burners
and circulating air passageways of the
appliance be kept clean.

4) See general construction and assembly

instructions. This appliance may only be
installed in a vented, noncombustible fi re-
place.

5) This appliance is Listed for bedroom instal-

lations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.

6) Always connect this appliance to a vent

system vent that is run (or routed) to the
outside of the building envelope. Never vent
to another room or inside a building. Make
sure that the vent is properly sized and is
of adequate height to provide the proper
draft.

7) Inspect the venting system annually for

blockage and any signs of deterioration.

8) Any glass removed for servicing must be

replaced prior to operating the appliance.

9) WARNING: Failure to position the parts

in accordance with the diagrams in this
manual or failure to use only parts specifi -
cally approved with this appliance may
result in property damage or personal
injury.

10) To prevent injury, do not allow anyone who

is unfamiliar with the operation to use the
fi replace.

Advertising