E33 FPI Direct Vent Gas Insert

MINIMUM CLEARANCES TO COMBUSTIBLES

From Unit

Side Walls

*

A 8" (203 mm)

Ceiling

B 47" (1194 mm)

Min. Mantel Height C 15" (381 mm)
Max. Mantel Depth D 3-1/2" (89 mm)

Alcove Width

E 76" (1930 mm)

Alcove Depth

F 36" (914 mm)

Hearth Height

G 1-1/4" (32 mm)

Hearth Width

H 45-1/2" (1156 mm)

Hearth Depth

I 13" (330 mm)

* Alcove side wall must have a min. of 8"
clearance on one side.

REGENCY FLUSH

COMBUSTIBLE MANTEL CLEARANCES

EXCALIBUR SURROUND & FULL SCREEN DOORS

COMBUSTIBLE MANTEL CLEARANCES

Mantel can be installed anywhere in shaded area or higher using the above scale.

Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour.

Because of the extreme heat this fi replace emits, the mantel clearances are critical.
Combustible mantel clearances from top of unit are shown in the above diagrams.

Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible

board.