Ricoh INFOPRINT XT GLD0-0025-01 User Manual

Page 154

Advertising
background image

AIOxxx293I

The

data

stream

converter

needs

Xerox

resource

resource_name

for

this

conversion.

Explanation:

InfoPrint

XT

did

not

find

a

required

Xerox

resource

during

job

conversion.

System

action:

InfoPrint

XT

cannot

complete

the

conversion.

User

response:

Make

sure

that

you

load

the

resource

on

the

system,

and

that

you

rerun

the

job.

You

might

also

receive

this

as

an

informational

message

when

you

scan

jobs

for

required

resources.

AIOxxx294W

A

record

in

file_name

was

longer

than

the

maximum

record

length

of

nn.

The

transform

ignored

data

in

bytes

beyond

the

expected

length.

Explanation:

A

logic

error

occurred

while

reading

from

file

file_name.

System

action:

InfoPrint

XT

cannot

process

the

request.

User

response:

Examine

the

file

and

make

sure

that

it

is

not

corrupt.

Make

sure

that

the

xcc

conversion

parameter

specifies

the

correct

type

of

carriage

control,

and

that

the

data

stream

conversion

parameters

are

correct.

Then,

do

the

operation

that

caused

this

error

again.

AIOxxx298U

A

program

or

operating

system

error

has

occurred.

Internal

diagnostic

information

follows:

error_info

error_info

Explanation:

A

logic

error

occurred.

InfoPrint

XT

supplies

a

phase

name,

diagnostic

information,

or

both,

to

help

identify

the

problem.

System

action:

The

process

fails.

User

response:

Report

this

message

to

your

technical

support

representative.

AIOxxx400I

Data

stream

converter

processing

aborted

due

to

unrecoverable

errors.

Explanation:

This

message

occurs

when

the

conversion

process

ends

abnormally.

Previous

messages

give

the

reason

for

abnormal

end

of

the

process.

AIOxxx404I

The

data

stream

converter

will

process

the

input

file

by

using

cc_type

carriage

control

characters.

Explanation:

InfoPrint

XT

examined

the

job

data

to

determine

whether

ANSI

or

IBM3211

control

characters

were

in

use.

The

type

of

controls

found

was

different

from

the

type

expected.

control_type

is

either:

v

ISO/ANSI/FIPS

v

IBM3211

(machine

code)

System

action:

InfoPrint

XT

continues

converting

the

job.

User

response:

Check

the

printed

output.

If

the

output

is

not

correct,

specify

the

correct

type

of

carriage

control

for

the

job.

Use

the

xcc

conversion

parameter.

Then,

convert

the

job

again.

AIOxxx407I

Reading

online

/

offline

JDL

query

parameters.

Explanation:

This

is

an

informational

message

that

indicates

that

InfoPrint

XT

has

begun

to

read

the

online/offline

JDL

query

parameters

to

determine

whether

the

job

is

an

online

or

offline

job.

It

requires

no

user

response.

AIOxxx408I

Reading

reformatted

Xerox

resource

dump

parameters.

Explanation:

This

is

an

informational

message

that

indicates

that

InfoPrint

XT

has

begun

to

read

the

reformatted

Xerox

resource

dump

parameters.

It

requires

no

user

response.

AIOxxx420S

UNDEFINEDFILE

condition

raised

on

name,

ONCODE

number.

Check

name

path

or

file.

Explanation:

InfoPrint

XT

did

not

find

the

input

file

for

the

job,

or

it

detected

incorrect

or

conflicting

attributes

for

the

file.

System

action:

The

process

fails.

User

response:

If

you

are

submitting

a

job

from

disk,

check

both

the

path

to

the

file

and

the

spelling

of

the

file

name

to

make

sure

that

the

path

and

file

exist.

If

you

are

manually

converting

the

job

with

the

pdxtx2afp

command,

also

make

sure

that

the

xrecfm

parameter

value

correctly

matches

the

fixed

or

variable

record

format

of

the

input

data,

and

that

the

xlrecl

parameter

value

is

in

the

valid

range

for

the

record

format.

If

the

problem

continues

after

you

have

verified

the

path

name,

file

name,

file

attributes,

and

parameter

values,

report

this

message

to

your

technical

support

representative.

AIOxxx421S

RECORD

condition

raised

on

file_name,

ONCODE

nn.

Check

file_name

file

attributes.

Explanation:

The

named

file

(file_name)

has

an

incorrect

record

format

(xrecfm=)

or

record

length

(xlrecl=)

specified

by

the

conversion

parameters

for

the

job.

System

action:

InfoPrint

XT

produces

no

output,

or

produces

incomplete

output.

134

InfoPrint

XT

Guide

|

|

Advertising