Ricoh INFOPRINT XT GLD0-0025-01 User Manual

Page 158

Advertising
background image

the

COLLATE

DJDE

in

the

input

file

and

reconvert

the

job.

AIOxxx563W

The

data

stream

converter

ignored

an

incorrect

COLLATE

change

request.

Explanation:

The

COLLATE

DJDE

that

InfoPrint

XT

found

is

not

valid

after

the

first

data

record

of

the

report.

System

action:

InfoPrint

XT

continues

processing

the

job.

User

response:

Make

sure

of

the

correct

placement

of

the

COLLATE

DJDE

in

the

input

file

and

reconvert

the

job.

AIOxxx564E

djde_name

-

DJDE

value

value

is

not

valid

for

the

specified

conversion

units.

Explanation:

InfoPrint

XT

cannot

process

the

value

value

correctly.

For

units

such

as

IN

(inches)

or

CM

(centimeters),

InfoPrint

XT

expects

no

more

than

three

decimal

places.

For

DOTS,

InfoPrint

XT

expects

an

integer

value.

System

action:

InfoPrint

XT

continues

processing

the

job,

but

the

output

might

not

be

correct.

User

response:

Round

any

decimal

values

to

three

decimal

places,

or

supply

integer

values

for

DOTS.

AIOxxx565E

djde_name

-

DJDE

value

input

is

not

valid

for

a

numeric

entry

field.

Explanation:

InfoPrint

XT

cannot

process

the

value

input

correctly.

InfoPrint

XT

does

not

process

the

DJDE

(djde_name).

DJDE

naming

conventions

require

a

numeric

entry

with

specific

rounding

values.

System

action:

InfoPrint

XT

continues

processing

the

job,

but

the

output

might

not

be

correct.

User

response:

Correct

the

value

and

reconvert

the

job.

AIOxxx566E

DJDE_keyword

DJDE

option_name

is

not

valid.

Explanation:

The

option_name

option

of

the

DJDE_keyword

DJDE

is

not

valid.

System

action:

InfoPrint

XT

ignores

the

DJDE

keyword

and

continues

processing.

User

response:

Correct

the

DJDE

and

reconvert

the

job.

AIOxxx567E

The

data

stream

converter

found

an

incorrect

copy

sensitive

change

request.

Explanation:

A

copy-sensitive

MODIFY,

FORMS,

or

BFORM

change

request

was

made

during

the

processing

of

the

current

report.

You

can

only

specify

copy-sensitive

MODIFY,

FORMS,

and

BFORM

commands

at

the

beginning

of

a

report.

The

program

ignores

the

request.

After

text

has

printed

on

a

copy-sensitive

report,

you

can

only

change

a

MODIFY,

FORMS,

or

BFORM

command

to

NONE.

System

action:

InfoPrint

XT

continues

processing

the

job,

but

the

output

might

not

be

correct.

User

response:

Correct

the

request

that

was

made

after

the

beginning

of

the

report

and

reconvert

the

job.

AIOxxx568E

The

data

stream

converter

could

not

find

graphic

image

resource_name

in

the

image

correlation

table

and

did

not

process

the

command

DJDE

command.

Explanation:

The

named

resource,

resource_name,

was

not

found.

The

resource

name

might

be

misspelled.

The

resource

might

not

be

loaded

on

the

InfoPrint

XT

server

or

it

might

have

been

loaded

as

a

resource

that

belongs

to

a

specific

resource

group.

System

action:

InfoPrint

XT

continues

processing

the

job,

but

the

output

might

not

be

correct.

User

response:

Check

the

spelling

of

the

resource

name.

Make

sure

that

the

resource

has

been

loaded

either

as

a

shared

resource

or

as

a

resource

that

belongs

to

a

specific

resource

group.

Then,

reconvert

the

job.

AIOxxx569E

The

data

stream

converter

found

incorrect

DJDE

command

command.

Explanation:

The

listed

command

(command)

is

not

a

known

DJDE

command,

or

its

specification

or

format

is

not

correct.

The

program

might

not

process

the

input.

System

action:

InfoPrint

XT

might

not

continue

to

process

the

job.

User

response:

Correct

the

command

and

reconvert

the

job.

For

SHIFT

or

XSHIFT

DJDEs

that

are

not

valid,

the

previous

front

or

back

side

SHIFT

or

XSHIFT

value

might

remain

in

effect.

The

DJDE

report

provides

details.

AIOxxx573W

Graphic

image

image_name

is

not

active.

The

data

stream

converter

did

not

process

the

command

command.

Explanation:

The

data

stream

converter

did

not

find

graphic

image

image_name

before

it

found

the

ALTER

or

CANCEL

command

for

the

image.

System

action:

InfoPrint

XT

might

not

continue

to

process

the

job.

User

response:

Correct

the

original

Xerox

job

so

that

it

uses

the

syntax

rules

for

graphic

images.

Then,

reconvert

the

job.

138

InfoPrint

XT

Guide

|
|
|
|
|

|
|

|
|

|

|

Advertising