Def sp – RAD Data comm ASMI-450 User Manual

Page 71

Advertising
background image

ASMi-450 Control from the Control Port

ASMi-450 Installation and Operation Manual

4-13

2. The password entry screen appears, e.g.:

NEW PASSWORD (4 to 8 CHARS) =
CURRENT PASSWORD = 'password'

where 'password' is the current password.

3. Type the required password. Carefully check that the specified password has been

indeed typed in, and then press <CR>. The ASMi-450 will display the TIME and
DATE fields, followed by the ASMi-450 prompt.

Note

Before entering a new password, make sure that the PSWD section of the
ASMi-450 internal switch S1 is not set to ON, because in such a case the default
password (ASMI) is enforced.

DEF SP-----------------------------------------------------------------------------------------

Purpose

Assign values to control port parameters. See Section 3-5 for parameter description and
allowable ranges, and Section 3-7 for practical selection recommendations.

Format

DEF SP

Use

1. Type

DEF SP<CR>

2. The first page of the control port parameters data form is displayed. A typical form is

shown below. The form presents the current parameter values as defaults.

SPEED

DATA

PARITY

INTERFACE

CTS

DCD_DEL

DSR

AUTO

8

NO

DCE

=RTS 0_MSEC

ON

3. Change the parameter values as follows:

Bring the cursor to the beginning of the first field to be changed by pressing the
space bar.

To change the selected field, press F or B to scroll among the available
selections.

When the desired selection is displayed, press the space bar to move to the next
field.

4. When done, press <CR> to display the next page of control port parameters. A typical

form is shown below.

POP_ALM

PWD

LOG_OFF

AUXILIARY DEVICE

NO

NO

NO

TERMINAL

5. Repeat the procedure given in Section 3 above to select new parameter values.