RAD Data comm ASMI-450 User Manual
Page 87

ASMi-450 Control from the Control Port
ASMi-450 Installation and Operation Manual
4-29
4.7 Configuration Error Messages
The ASMi-450 provides configuration error messages for the control terminal
user. The configuration messages have the format ERROR, followed by a two-
digit code. The ASMi-450 will display a short description of the error message
after the ERROR code.
The error messages are explained below.
ERROR 01
ILLEGAL LOOP COMBINATION
Illegal combination of loopbacks: you are trying to activate simultaneously
local and remote loopbacks. Only one loopback can be connected at a time.
ERROR 02
REM REM LOOP WHILE SYNC LOSS
You are trying to activate REM REM loopback while synchronization is lost.
ERROR 03
ILLEGAL CLOCK MODE ON REMOTE SIDE
You are trying to select the internal clock mode at the remote side.
ERROR 04
LOOP IS NOT ACTIVE
You are trying to disconnect a loopback that is not active.
ERROR 06
ILLEGAL NODE NUMBER
You are trying to select a node number greater than 255.