Installation, Venting arrangements, Inst alla tion – Regency Liberty L900-1 User Manual

Page 15

Advertising
background image

Regency

®

L900-1 Direct Vent Gas Fireplace

15

INST

ALLA

TION

INSTALLATION

VENTING ARRANGEMENTS

HORIZONTAL TERMINATION (FLEX)

Regency

®

Direct Vent System

These venting systems, in combination with the L900-1, have been tested and listed as a direct vent system by Warnock Hersey. The location of the
termination cap must conform to the requirements in the Vent Terminal Locations diagram from the "Exterior Vent Termination Locations" section.

FPI Direct Vent (Flex) System Termination Kits include all the
parts needed to install the L900-1 using a fl exible vent.

Notes:
1) Liner sections should be continuous without any joints

or seams.

2) Only Flex pipe purchased from FPI may be used for Flex

installations.

3) Horizontal vent must be supported every 3 feet.

4) A wall thimble is mandatory for all horizontal terminations

due to high temperatures.

FPI Kit #

Length Contains:

#946-615

4 Feet

1) 8”

fl exible liner (Kit length)

2) 5”

fl exible liner (Kit length)

3) spring

spacers

4) thimble
5) AstroCap termination cap
6) screws
7) tube of Mill Pac
8) plated

screws

9) S.S. screws #8 x 1-1/2” drill point
10) vinyl siding standoff

#946-618

6 Feet

#946-616

10 Feet

Advertising