Regency

®

L900-1 Direct Vent Gas Fireplace

27

INST

ALLA

TION

WIRING DIAGRAM

AERATION ADJUSTMENT

The burner aeration is factory set but may need
adjusting due to either the local gas supply or
altitude. Open the air shutter for a blue fl ame or
close for a more yellow fl ame.

In order to adjust the aeration, the logs, grate
and burner will need to be removed to be able
to access the shutters.

Minimum Air Shutter Opening:

NG 1/8"
LP 1/2"

CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can
cause improper and dangerous operation.

Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.

CAUTION: Carbon will be produced if air shutter

is tightly closed.

Note: Any damage due to carboning

resulting from improperly setting
the aeration controls is NOT covered
under warranty.

INSTALLATION

NOTE: The #8 ground lug is located on

the outer left side of the unit.