Type tests, Iec 61850-3 type tests – RuggedCom M2100 User Manual
Page 24

4. Type Tests
RuggedCom® RuggedSwitch®
24
M2100 Installation Guide Rev 1.0
4. Type Tests
4.1. IEC 61850-3 Type Tests
Test
Description
Test Levels
Severity
Levels
Enclosure Contact
± 8 kV
4
IEC 61000-4-2
ESD
Enclosure Air
± 15 kV
4
IEC 61000-4-3
Radiated RFI
Enclosure Ports
20 V/m
X
Signal ports
± 4 kV @ 2.5kHz
X
DC Power ports
± 4 kV
4
AC Power ports
± 4 kV
4
IEC 61000-4-4
Burst (Fast
Transient)
Earth ground ports
± 4 kV
4
Signal ports
± 4 kV line-to-earth, ± 2 kV line-to-line
4
DC Power ports
± 2 kV line-to-earth, ± 1 kV line-to-line
3
IEC 61000-4-5
Surge
AC Power ports
± 4 kV line-to-earth, ± 2 kV line-to-line
4
Signal ports
10 V
3
DC Power ports
10 V
3
AC Power ports
10 V
3
IEC 61000-4-6
Induced
(Conducted) RFI
Earth ground ports
10 V
3
IEC 61000-4-8
Magnetic Field
Enclosure Ports
40 A/m, continuous, 1000 A/m for 1 s
N/A
DC Power ports
30% for 0.1 s, 60% for
0.1 s, 100% for 0.05 s
N/A
IEC 61000-4-29
Voltage Dips
& Interrupts
AC Power ports
30% for 1 period, 60% for 50 periods
N/A
IEC 61000-4-11
Voltage Dips
& Interrupts
AC Power ports
100% for 5 periods, 100% for 50 periods
N/A
Signal ports
2.5 kV common, 1 kV diff. mode @ 1 MHz
3
DC Power ports
2.5 kV common, 1 kV diff. mode@1MHz
3
IEC 61000-4-12
Damped Oscillatory
AC Power ports
2.5 kV common, 1 kV diff. mode @ 1 MHz
3
Signal ports
30 V Continuous, 300 V for 1 s
4
IEC 61000-4-16
Mains Frequency
Voltage
DC Power ports
30 V Continuous, 300 V for 1 s
4
IEC 61000-4-17
Ripple on DC
Power Supply
DC Power ports
10%
3
Signal ports
2 kVAC (Fail-Safe Relay output)
N/A
IEC 60255-5
Dielectric Strength
DC Power ports
1.5 kVDC
N/A