Troubleshooting, Standby power indicator is not lit, Fuse replacement – ROTEL RC-1082 User Manual

Page 9: No sound, Specifications, Specifications, English

Advertising
background image

9

NOTE: By default, the RR-AT97 operates
the Rotel RT-1080/RT-961/RT-955 tuners.
The remote can be reprogrammed to oper-
ate the RT-940AX tuner. This programming
only needs to be done once:

To program for the RT-940AX: press
the ON button and the 2 button simultane-
ously.

To program for the RT-1080/

RT-961/RT-955: press the ON button
and the 1 button simultaneously.

Troubleshooting

Most difficulties in audio systems are the result
of incorrect connections, or improper control
settings. If you encounter problems, isolate the
area of the difficulty, check the control settings,
determine the cause of the fault and make the
necessary changes. If you are unable to get
sound from the RC-1082, refer to the sugges-
tions for the following conditions:

Standby Power Indicator Is

Not Lit

The Standby Power Indicator should be lit
whenever the RC-1082 is plugged into the
wall power outlet. If it does not light, test the
power outlet with another electrical device,
such as a lamp. Be sure the power outlet be-
ing used is not controlled by a switch that has
been turned off.

Fuse Replacement

If another electrical device works when plugged
into the power outlet, and the Standby Indicator
still will not light when the RC-1082 is plugged
into the wall outlet, it indicates that the internal
power fuse may have blown. If you believe this
has happened, contact your authorized Rotel
dealer to get the fuse replaced.

No Sound

Check the signal source to see if it is functioning
properly. Make sure the cables from the signal
source to the RC-1082 inputs are connected
properly. Be sure the Listening Selector is set
to the proper input. Check the power ampli-
fier for power and proper operation. Check
all the wiring between the RC-1082 and the
power amplifier, and the power amplifier
and speakers.

English

Specifications

Total Harmonic Distortion (20Hz-20kHz)

< 0.004%

Intermodulation Distortion (60 Hz : 7 kHz, 4:1)

< 0.004% at 1V output

Input Sensitivity / Impedance

Phono - MC

250 µV / 100 ohms

Phono - MM

2.5 mV / 47 kOhms

Line Level

150 mV / 220 kOhms

Phono Overload (MC/MM)

16 mV / 160 mV

Output Sensitivity / Impedance

1 V/ 100 Ohms

Frequency Response

Phono Input

20Hz-20kHz, ± 0.2dB

Line Level Input

4Hz-100kHz, ± 0.5dB

Signal to Noise Ratio (IHF “A” weighted)

Phono - MC/MM

70 dB/75 dB

Line Level

100 dB

Power Requirements

USA Version

120 Volts, 60 Hz

European Version

230 Volt, 50 Hz

Power Consumption

15 Watts

Standby Power Consumption

2.5 Watts

Dimensions (W x H x D)

432 x 92 x 344 mm

17 x 3

5

/

8

x 13

9

/

16

Weight (net)

7.5 kg, 16.53 lbs.

All specifications are accurate at the time of printing.
Rotel reserves the right to make improvements without notice.

Advertising