Roberts Gorden Blackheat UHA-Series 30 User Manual

Page 34

Advertising
background image

UHA L

OW

P

ROFILE

U

NIT

H

EATER

I

NSTALLATION

O

PERATION

AND

S

ERVICE

M

ANUAL

28

9.7 Electrical Connection to the Heater

IMPORTANT: Junction box is not provided with heater.
Conduit can also be attached directly to heater with wire junction made within the heater cabinet.

BX Connector

Junction Box

Flexible Conduit

Burner

Connect wires together

with suitable approved

wire connectors.

Green to Ground

White to L2

Black to L1

L1
L2

Ground

Black

White

Green