SECTION 14: R

EPLACEMENT

P

ARTS

43

14.2 Burner Compartment

14.2.1 Burner Injectors

Remove flexible
air duct from spigot

Viewing port
for flame probe

Flame Probe

Burner
Compartment
Cover

Ignition Electrode

Remove screws and
pull off burner cover

NOTE: Separated combustion
model

shown.

The burner compartment is a sealed
compartment. Following any work,
re-seal the compartment with the
gas pipe rubber seal fully in place
and all screws fitted and tight.

.

MODEL

UHA[X][S] 30

UHA[X][S] 45

UHA[X][S] 60

UHA[X][S] 75

UHA[X][S] 100

UHA[X][S] 125

Orifice Quantity

2

3

4

5

6

7

Natural Gas (G20)

Orifice Marking

49

49

49

49

46

46

P/N

91930049

91930049

91930049

91930049

91930046

91930046

Propane (G31)

Orifice Marking

56

56

56

1.15 mm

1.25 mm

1.25 mm

P/N

91930056

91930056

91930056

91930115

91930125

91930125

Remove manifold

screws and pull

out manifold

Manifold

Inshot

Burners

Orifices

Manifold

Mounting

Bracket

Grommet

Unscrew

Orifices

Manifold

Marking

Folded

Hem

Ensure gas tight fitting of
injectors.
Ensure correct

alignment

with burners.
Ensure all pipe joints are
gas tight.