Non-standard tier configuration – Raritan Computer II User Manual

Page 68

Advertising
background image

58

P

ARAGON

II U

SER

M

ANUAL

Non-Standard Tier Configuration

Guidelines for Existing Firmware Versions

•

Non-Standard tier configurations are those configurations supported by Paragon II, but require special
procedures in order to function properly. These include:

−

Triangle Configuration

−

Diamond Configuration

−

Redundant Configuration

•

When a Non-Standard tier configuration is detected, Paragon will do the following:

−

Display the message “Illegal Connect/Check CTxxxxxx” on the LCD panel, where CTxxxxxx is
the serial number of UMT that has the Non-Standard configuration on its user ports

−

Stop normal function and continue displaying the message until the connection is removed and the
unit is reset

−

While the UMT is trapped on the message, it will send the broadcasting message to all UST1s
every two (2) seconds, “Illegal connection on CTxxxxxx”

−

The message will also appear on the OSD until the Non-Standard tier configuration is removed

•

Recovery:

−

After any re-connection subsequent to the Non-Standard tier configuration, all UMT Matrix
Switches should undergo a FUNC reset to clear the switch database. This procedure should be
performed starting from the third tier device down to the base unit.

−

Whenever a third tier UMT Matrix Switch is replaced, all of the second tier and base UMT Matrix
Switches should undergo a FUNC reset.

−

Whenever a second tier UMT Matrix Switch is replaced, all of the base UMT Matrix Switches
should undergo a FUNC reset.

−

Whenever a base UMT Matrix Switch is replaced, only the new UMT Matrix Switch should
undergo a FUNC reset.