Installation, Installation of the dc sparker – Regency NATURAL GAS U32-NG4 User Manual

Page 15

Advertising
background image

15

U32-4 FPI Direct Vent Gas Insert

Installation of the DC Sparker:

16) Verify that if the conversion is from

NG to LPG, the screw must be re-
assembled with the red o-ring visible
(Fig. 5).

LPG Configuration

Red o-ring visible

Fig.5

17) Re-assemble the black protection

cap (Fig. 6).

Fig. 6

WARNING!

Also check that the pilot and main

burner injectors are appropriate for

the gas type.

19) Attach the label "This unit has been

converted to LPG" near or on top of the
serial # decal.

20) Replace yellow "NG" label with red

"LPG" label.

21) Locate the Piezo Ignitor situated at the

side of valve.

22) Remove the Piezo Ignitor by unscrewing

the nut at the back of the mounting
bracket.

23) Disconnect the ignitor wire from the

Piezo Ignitor and connect it to the DC
Sparker.

Piezo

Ignitor

Ignitor

Wire

Piezo

Ignitor

Ignitor

Wire

DC

Sparker

24) Install the 3/4" nylon plug to cover up the

hole on the mounting bracket.

18) Reverse

step

2).

9)

Reinstall new burner orifi ce LPG
stamped #52 and tighten.

10) Turn control knob to the “OFF” position.

Fig. 1

11) Remove the black

protection cap by hand
from the hi-low knob
(Fig.1).

Fig.2

14) Flip the screw (Fig. 3).

Fig.4

Fig.3

15) Using the Allen wrench

as shown in Fig.4, rotate
the screw clockwise until
snug, do not overtighten.

12) Insert a 5/32” or 4mm

Allen wrench into the
hexagonal key-way
of the screw (Fig.
2), rotate it counter-
clockwise until it is free
and extract it.

13) Check that the screw is clean and if

necessary remove dirt.

WARNING!

Do not over tighten the screw.

Recommended to

grip the wrench by the short side.

INSTALLATION

Advertising