Installation, Manufactured mobile home additional requirements, Materials required – Regency NATURAL GAS U32-NG4 User Manual

Page 7: Installation checklist, Minimum fireplace dimensions, Clearances to combustibles

Advertising
background image

7

U32-4 FPI Direct Vent Gas Insert

A

B

D

E

C

MANUFACTURED

MOBILE HOME

ADDITIONAL

REQUIREMENTS

1) Ensure that structural members are not cut

or weakened during installation.

2) Ensure proper grounding using the #8

ground lug provided.

3) Appliance must be anchored to the fl oor

with the supplied anchoring methods.

MATERIALS REQUIRED

No electrical power supply is required for the gas
control to operate. A 120 Volt AC power cord is
hooked up to the fan. Plug the 3 wire cord into
a suitable receptacle. Do not cut the ground
terminal off under any circumstances.
When
connected with 120 volts, the appliance must be
electrically grounded in accordance with local
codes, current version of CSA C22.1 (in Canada)
or in the absence of local codes, with the National
Electrical Code ANSI/NFPA 70-1987.

INSTALLATION

INSTALLATION

CHECKLIST

Before installing vent system ensure that the
damper plate is open and secure to prevent the
damper plate from falling down and crushing
the liner.

The FPI Gas Insert is installed as listed.
1) Check all clearances to combustibles, (Refer

to sections "Minimum Fireplace Dimensions
and Clearances to Combustibles)

2) Make the gas connection. (Refer to section

"Gas Connection")

3) Install the 3" flue liner to the sliding

connector plate. (Refer to section "Flue
Liner Installation.")

4) Slide the unit half way into the fi replace.

5) Pull the vent connector plate through the

tapered brackets and fasten to the front plate.
Refer to section "Flue Liner Installation.")

6) Slide the unit fully into the fi replace.

7) Test gas pressure (Refer to section "Gas

Pipe Pressure Testing"). Check aeration
system (Refer to section "Gas Insert Aeration
System").

8) Install standard and optional features. Refer

to the following sections:

a.

Brick

Panel

b. Lot Set

c.

Faceplate

&

Trim

d. Standard Flush Door

e.

Flush

Trim

f. Double Screen Door

g.

Flush

Louvers

h.

Bay

Louvers

i. Bay Door

j.

Bay

Trim

k. Full Screen Doors

l.

Hampton

Cast

Faceplate

m.

Hampton

Cast

Grills

n. The Kensington Front

o.

Wall

Thermostat

p. Remote Control

9) Final check: Before leaving this unit with the

customer, the installer must ensure that the
appliance is fi ring correctly. This includes:

a) Clocking the appliance to ensure the

correct fi ring rate.

b) Adjusting the primary air, if required, to

ensure that the fl ame does not carbon.
See "Gas Insert Aeration System"
section.

c) Ensuring that the appliance is venting

correctly.

MINIMUM FIREPLACE

DIMENSIONS

The minimum fi replace clearances & dimensions
for the FPI gas insert are shown in the following
diagrams:

Diagram 1

Combustible Mantel Clearances

with Bay & Flush Louvers in

Masonry and Factory Built

Fireplace Installation

Diagram 2

CLEARANCES TO

COMBUSTIBLES

Minimum Clearances to Combustibles

From Unit
Sides

A

10" / 255 mm

Ceiling

B

47.5" / 1205 mm

Mantel

C

see Dia. 2 & 3

From Standard Surround (26" x 40")
Sides

D

4" / 100 mm

Ceiling

E

41.5" / 1055 mm

Mantel

see Dia. 2 & 3

Max. Mantle Depth

G

12" / 305 mm

(see Dia. 2)

Hearth Height

H

0" / 0 mm

Hearth Depth

I

16" / 405 mm

Hearth Width

J

40" / 1015 mm

Max Lentil
Bar Depth

A

Height

B

Depth

C

Width

(rear)

D

Width
(front)

E

Regency

Countour

Faceplate

9"

22"

14"

22-1/2"

26-1/2"

Regency

Molded

Faceplate

10"

22"

15"

22-1/2"

29"

Palace

Front

10"

22"

15"

22-1/2"

29"

Hampton

Cast

Faceplate

9"

22"

14"

22-1/2"

26-1/2"