Edit mode (EDIT)

Bend Pitch Control

fig.checksum

Since the GS Bend Pitch Control message has a data
range of 40H–58H (0–24 semitones), we will select

Advanced mode 1

, which lets us specify the range.

Since the data format is one byte, we will select
“DT0” (p. 161) when inserting the data.

1. Press the

[EDIT]

button.

The display will indicate “EDT”.

2. Slightly move the controller to which you want to assign the system exclusive message. In the case of a

button, press that button.
The display will indicate the number of the selected controller.

3. Confirm what’s indicated and press

[ENTER]

.

4. Press the

[SYSTEM Ex.]

key, and then press the

[1]

key.

The display will indicate “SE1”.

5. Confirm what’s indicated and press

[ENTER]

.

The display will blink “F0”, which is the first byte (beginning status) of a system exclusive message.
(This cannot be changed.)

6. Confirm what’s indicated and press

[ENTER]

.

7. Use the

[4]

and

[1]

keys to input the second byte “41”.

8. Confirm what’s indicated and press

[ENTER]

.

Input the third, fourth and fifth bytes in the same way.

9. Since the sixth byte is the beginning of the checksum calculation area, press the

[CHECKSUM]

key to specify

this byte as the beginning of the area for which the checksum will be calculated.

10. Confirm what’s indicated and press

[ENTER]

.

11. Input the sixth byte.

12. Since the seventh byte will have “2” in the upper bits and the block number in the lower bits, press

[DATA]

three times.
The display will indicate “0BL”.

F0 41 10 42 12 40 2x 10 DATA SUM F7

Address

Data

Checksum

Block number

1 byte

Checksum calculation region