Omega Vehicle Security freedom OM-550 User Manual

Page 41

Advertising
background image

OM-550

u

36

u

3. Next, find m & b:

X1

= 0 VDC

ç minimum expected input

=

0 A/D counts

at Transducer minimum output

X2

= 2.0000 VDC

ç maximum allowable input

=

20000 A/D counts

at Transducer maximum output

Y1

= 20.00 %RH

ç choose decimal point = 2

=

2000 display counts

Y2

= 90.00 %RH

ç keep decimal point = 2

=

9000 display counts

[Desired % RH resolution 2 places to right

m

= (Y1 - Y2) / (X1 - X2)

of the decimal point (.01% RH)]

=

(2000 - 9000) / (0 - 20,000)

=

0.35000

b =

Y2 - (m * X2)

=

9000 - (0.350 * 20,000)

=

002000

4. Programming for the previous example:

Figure 4-10

PRESS 1

PRESS V

PRESS YES

PRESS 035000

PRESS YES

PRESS 002000

PRESS 58

PRESS 2

THE FINAL CHANNEL
DESCRIPTION

PRESS THE

EXIT

KEY AND IT IS ECHOED

Advertising