14

O.A.S. 2007

c

10 HP Pulley Drive Owner’s Manual

Maintenance of Fan / Blower

(Cont.)

2.) Cleanliness - Keep both the interior and exterior of the motor free from dirt, water, oil and grease.

3.) Safety - Motors should be installed, protected and fused in accordance with latest issue of

National Electrical Code, NEMA Standard Publication No. MG2 and local codes. Rotating parts such

as pulleys, coupling, external fans, and unusual shaft extensions should be permanently guarded.

Keep hands and clothing away from moving parts. Electrical repairs should be made by trained,

qualified personnel only.
4.) Location - The free flow of air around the motor should not be obstructed. The motor should

never be placed in a room with hazardous processes, or where flammable gases or combustible

material may be present, unless it is specifically designed for this type of service.

5.) V-Belt Drive -

A.) Align sheaves carefully to avoid axial thrust on motor bearing. The drive sheave on the motor

should be positioned toward the motor so it is as close as possible to the bearing.

B.) When adjusting belt tension, make sure the motor is secured by all mounting bolts before

tightening belts.

C.) Adjust belt tension to belt manufacturers recommendations. Excessive tension will shorten

bearing life. Insufficient tension shortens bearing life, can reduce fan performance and may

cause vibration. Belts may slip during start-up, but slipping should stop when fan reaches full

speed.

X

Y

E

D

C

Key “E” locks moveable

side(s) of sheave after

pulley has been adjusted.

Do not operate

Sheave with flange

projecting beyond

the hub end.

6.) Condensation Drain Plugs - All explosion proof and totally enclosed motors are equipped with

automatic drain plugs, which should be kept free of oil, grease, paint, grit and dirt. The drain system

is designed for normal floor (feet down) mounting. For other mounting positions, modification of the

drain system may be required. Consult the manufacturer.

7.) The factory installed bearings in the motor are double shielded (permanently sealed), pre-

lubricated, ball bearings without grease fittings and don’t need relubrication. The bearing part

numbers are as follows: Drive End / 6309ZZ, Opposite Drive End / 6307ZZ. If the bearings ever

need replacing, the motor should be taken to an EASA (Electrical Apparatus Service Association)

certified shop to ensure proper installation.

D.) Sheaves should be in accordance to NEMA Spec. MG-1 or as approved by the manufacturer

for a specific application.

Adjusting:

1.) Loosen setscrews “Y” and “C” in moving parts of sheave. Turn pulley so Key ‘E’ drops down & out of the way.

2.) Adjust sheave pitch diameter for desired speed by opening moving parts 1/2 or full turns from closed position.

Do not open more than six full turns for “B” belts.

3.) Tighten setscrew “Y” over key and setscrew “C” over flat surface machined into sheave center hub.

Torque set screws to the following values: 100 in. lbs. minimum to 130 in. lbs. maximum.

4.) Put on belts after elevating motor mount plate and adjust belt tension to proper value. Do not force belts over

grooves.)

5.) Future adjustments should be made by loosening the belt tension and increasing or decreasing the pitch diameter

of the sheave by half or full turns as required. Readjust belt tension before starting drive.

6.) Be sure that all keys are in place and that all setscrews are torqued properly before starting drive. Check

setscrews and belt tension after 24 hours of service.

7.) Replace shaft and pulley guards covers.

Set screw ‘X’ locks

sheave to motor shaft.

Replacement Belt Part Numbers

10hp
15hp

B44 Belt
BX44 Belt

BLZ440000
BLZ440001

Advertising