Display above the ceiling – SUUNTO Stinger User Manual
Page 46

44
Fig. 3.20. Decompression dive,
above ceiling. Note downward
pointing arrow, Er warning and
an audible alarm. You should
immediately (within 3 minutes)
descend to or below ceiling.
only after the ASC TIME and CEILING labels have
disappeared, which means that the decompression stop
and any Mandatory Safety Stop has been completed.
You are advised, however, to stay until the STOP sign
has also gone. This indicates that the three minute
Recommended Safety Stop has also been completed.
DISPLAY ABOVE THE CEILING
If you ascend above the ceiling during a decompression
stop, a downward pointing arrow will appear and a
continuous beeping starts (Fig. 3.20.). In addition, an
error warning Er reminds you that you have only three
minutes to correct the situation. You must immediately
descend to or below the ceiling.
If you continue to violate the decompression, the dive
computer goes into a permanent Error Mode. In this
mode the instrument can only be used as a depth gauge
and timer. You must not dive again for at least 48 hours
(see chapter 3.2.5.).