OSBURN HYBRID-45 MF FREESTANDING PELLET STOVE


Width: 27”
Height: 30 1/2”
Depth: 24 5”
Weight: 230 lbs.
Flue size: 3” or 4”
Hopper Capacity: Up to 70 lbs.
(This can vary widely depending on pellet size, length, and diameter)
EPA status: exempt
Burn rate: 1 lb. to 5.5 lbs. per hour
BTU range: 8,200 to 45,000
Electrical consumption: 3.5 Amps lighting cycle
2.5 Amps. continuous duty
Control board fuses: Main: 7.5A-250V fastblow
Igniter: 5A-250V fastblow
Electrical requirement: 120VAC 15A
Approved installations: mobile home, conventional

PREPARATION


Factory packaging must be removed, and some minor assembly work is required
prior to installation:

The door overlay must be installed on the door frame;

The louver kit must be installed in front of the heat exchanger.


NOTE: Normally, your dealer will perform these functions.

CLEARANCES


The Osburn Hybrid-45 MF has been tested and listed for installation in residential,
mobile home.(refer figure 1 & 2)

FLOOR PROTECTION: minimum 6” in the front and 6” on each side. The stove
must be placed on a continuous (grouted joints) noncombustible material such as
ceramic tile, cement board, brick, 3/8” millboard or equivalent, or other approved or
listed material suited for floor protection. NOTE: ceramic tile, or any tile, requires a
continuous sheet beneath to prevent the possibility of embers falling through to the
combustible floor if cracks or separation should occur in the finished surface, this
would include floor protection for Built-in raised hearths. Check local codes for
approved alternatives.

Clearances are measured from the sides, back and face (door opening) or stove
body (refer to fig. 3).

DO NOT USE MAKESHIFT MATERIALS OR COMPROMISES IN THE
INSTALLATION OF THIS UNIT.

INSTALL VENT WITH CLEARANCES SPECIFIED BY THE VENT
MANUFACTURER.

3"

2" *

6"

SIDE

W

A

L

L

BACK WALL





2"

3"

3"

2"

ADJACENT WALL

AD
JA
CENT

W
A

LL







6"

6"

6"







INSTALLATION

5

FIGURE 1

Back wall installation

FIGURE 2

Corner installation

FIGURE 3

Floor protection