Omega Vehicle Security CN3271 Series User Manual

Page 26

Advertising
background image

23

STANDARD RANGES TABLE

D) LOGIC INPUTS

D) LOGIC INPUTS

D) LOGIC INPUTS

D) LOGIC INPUTS

D) LOGIC INPUTS
(for models with RS-485 only)

(for models with RS-485 only)

(for models with RS-485 only)

(for models with RS-485 only)

(for models with RS-485 only)
This instrument is provided of 1 logic input used
for remote acknowledgement.
NOTES

NOTES

NOTES

NOTES

NOTES
1) Use an external dry contact capable of

switching 0.5 mA, 5 V DC.

2) The instrument needs 100 ms to recognize a

contact status variation.

3) The logic inputs are NOT

NOT

NOT

NOT

NOT isolated by the

measuring input.

OUTPUTS

OUTPUTS

OUTPUTS

OUTPUTS

OUTPUTS

Output updating time

Output updating time

Output updating time

Output updating time

Output updating time :
- 250 ms when a linear input is selected
- 500 ms when a TC or RTD input is selected.

OUTPUT 1

OUTPUT 1

OUTPUT 1

OUTPUT 1

OUTPUT 1
Type: relay

Type: relay

Type: relay

Type: relay

Type: relay SPDT contact .
Contact rated

Contact rated

Contact rated

Contact rated

Contact rated: 3 A at 250 V AC on resistive load.
Function

Function

Function

Function

Function: Safety limiter output.
Action

Action

Action

Action

Action: reverse (fail-safe).

OUTPUT 2

OUTPUT 2

OUTPUT 2

OUTPUT 2

OUTPUT 2
Type: relay

Type: relay

Type: relay

Type: relay

Type: relay SPST contact .
Contact rated

Contact rated

Contact rated

Contact rated

Contact rated: 2 A at 250 V AC on resistive load.
Function

Function

Function

Function

Function: Alarm output
Action

Action

Action

Action

Action: direct/reverse programmable by front

keyboard.

ALARM

ALARM

ALARM

ALARM

ALARM

Action

Action

Action

Action

Action: Direct or reverse acting.
Alarm functions

Alarm functions

Alarm functions

Alarm functions

Alarm functions: configurable as process alarm,
band alarm or deviation alarm.
Alarm reset

Alarm reset

Alarm reset

Alarm reset

Alarm reset: automatic reset, manual reset or
"Silence" function is programmable.
Stand by (mask) alarm

Stand by (mask) alarm

Stand by (mask) alarm

Stand by (mask) alarm

Stand by (mask) alarm: the alarm can be
configured with or without stand by (mask)
function.

Process alarm

Process alarm

Process alarm

Process alarm

Process alarm:
Operative mode

Operative mode

Operative mode

Operative mode

Operative mode : High or low programmable.
Threshold

Threshold

Threshold

Threshold

Threshold : programmable in engineering unit within
the readout span.
Hysteresis

Hysteresis

Hysteresis

Hysteresis

Hysteresis: programmable from 0.1 % to 10.0 % of
the readout span.

Input type

Input type

Input type

Input type

Input type

15
16
17
18
19
20
21
22

0 - 60 mV

0 - 60 mV

0 - 60 mV

0 - 60 mV

0 - 60 mV

12 - 60 mV

12 - 60 mV

12 - 60 mV

12 - 60 mV

12 - 60 mV

0 - 20 mA

0 - 20 mA

0 - 20 mA

0 - 20 mA

0 - 20 mA
4 - 20 mA

4 - 20 mA

4 - 20 mA

4 - 20 mA

4 - 20 mA

0 - 5 V

0 - 5 V

0 - 5 V

0 - 5 V

0 - 5 V
1 - 5 V

1 - 5 V

1 - 5 V

1 - 5 V

1 - 5 V
0 - 10 V

0 - 10 V

0 - 10 V

0 - 10 V

0 - 10 V
2 - 10 V

2 - 10 V

2 - 10 V

2 - 10 V

2 - 10 V

impedance

impedance

impedance

impedance

impedance

> 1 M

< 5

> 400 k

> 400 k

Accuracy

Accuracy

Accuracy

Accuracy

Accuracy

0.2 % + 1 digit

@ 25°C

(77 °F)

LHL-1-NEUTRO.pmd

19/04/2004, 15.07

23

Advertising