Quantum Audio Travan 40 Tape Drive STT3401A User Manual

Page 47

Advertising
background image

ATAPI Interface

Chapter 5

Seagate Travan 40 Product Manual

Page 39

D

Parameter Code

LSB

01

E

DU

DS

TSD

ETC

TMC

0

LP

40

F

Parameter Length

04

10
11
12
13

MSB

Total Errors Corrected

LSB

XX
XX
XX
XX

NOTE: (Total Blocks Recovered by ECC) + Total Errors Corrected = Total Blocks Read

Page 03—Error Counter for READ definitions

Byte

00

Page Code

Set to 03h.

01

Reserved

Set to 00h.

02-03

Additional Page Length

Set to 1Ch.

04-05

Parameter Code

0000h—# of block recovered by ECC alone
0001h—# of blocks recovered without using ECC
0002h—total # of rereads
0003h—total errors corrected
0004h—# of frames corrected by ECC alone
0005h—total # of bytes processed
8004h—total # of bytes corrected by ECC

06

DU

The Disable Update bit is always set to 0, indicating the drive
updates parameter values for all events.

DS

The Disable Save bit is always set to 1, indicating the drive
does not save parameter values.

TSD

The Target Save Disable bit is always set to 0 indicating the
drive defines a method for saving log parameters.

ETC

The Enable Threshold Comparison bit is always set to 0,
indicating comparison to the threshold value is not performed
whenever the cumulative value is updated.

TMC

The Threshold Met Criteria bits are used with the ETC bit and
are always set to 0.

LP

The List Parameters bit is always set to 0, indicating all
parameters are data counters.

07

Parameter Length

Set to 02h, indicating 2 bytes in the counter.

08-09

Total Re-Reads

(*)

Total number of uncorrectable frames. An uncorrectable
frame will generate a Re-Read recovery sequence.

0E-10

Total Errors Corrected

(*)

Total number of frames corrected is the sum of the number of
frames corrected by ECC plus the number of frames corrected
by the Re-Read recovery procedure.

15-16

Frames Corrected By
ECC Alone

(*)

The total number of frames containing one or more blocks that
failed the CRC check. For the total number of blocks, see
REQUEST SENSE.

1B-1F

Total Bytes Processed

(*)

The transfer length of all Fixed Block Mode READ commands
times the block length specified in Mode Data plus the total
transfer length of all Variable Block Mode READ commands.

1B-1F

Total Bytes Corrected
by ECC

(*)

The total number of bytes corrected by ECC during all READ
commands.

Advertising
This manual is related to the following products: