Quantum Audio Travan 40 Tape Drive STT3401A User Manual

Page 56

Advertising
background image

Chapter 5

ATAPI Interface

Page 48

Seagate Travan 40 Product Manual

Data Bits

Byte

7

6

5

4

3

2

1

0

Hex

34

Parameter Length

04

35


38

MSB

Longest Time Between Cleanings

(in Minutes)

LSB

XX
XX
XX
XX

39

3A

MSB

Parameter Code

LSB

00

06

3B

DU

DS

TSD

ETC

TMC

0

LP

40

3C

Parameter Length

02

3D

3E

MSB

Cleaning Interval (in Minutes)

LSB

XX

XX

Page 33h—Special Information Definitions

Byte

00

Page Code

Set to 31h.

01

Reserved

Set to 00h

02-03

Additional Page
Length

Set to 1Eh.

04-05

Parameter Code

Set to 00 00h, indicating the first parameter follows.

06

DU

The Disable Update bit must be set to 0, indicating the drive
updates parameter values for all events.

DS

The Disable Save bit is always set to 1, indicating the drive does
not save parameter values.

TSD

The Target Save Disable bit is always set to 0 indicating the
drive defines a method for saving log parameters.

ETC

The Enable Threshold Comparison bit is always set to 0,
indicating comparison to the threshold value is not performed
whenever the cumulative value is updated.

TMC

The Threshold Met Criteria bits are used with the ETC bit and
are always set to 0.

LP

The List Parameters bit is always set to 1, indicating the
parameter is a list parameter.

07

Parameter Length

Set to 0Ch, indicating 12 bytes in the counter.

08-13

Unit Serial Number

Set to the ASCII value of the drive’s ten-digit serial number. The
ten-digit value is interpreted as follows: PPSYWWNNNN.
Where: PP is the product code, i.e., TG is NS20 SCSI.
S is the manufacture location, i.e., T is Thailand.
Y is the last digit of the calendar year, i.e., 8 is 1998.
WW is the calendar week.
NNNN is the alphanumeric serial number.
(The serial number markings are detailed in document 44872.)

18-1A

Cartridge Insertions

The number of physical loads of any cartridge type during the
life of the drive. The number of cartridge loads includes cleaning
cartridge loads and failed load attempts. The field is never reset.