Important information, Quartz thermo installation guide, Introduction – Quartz QZ3111 User Manual

Page 3: Safety information, Flushing, Connections, Isolating valves, Filters, Siting

Advertising
background image

Quartz Thermo installation guide

page 3

Important information

Introduction

The Quartz Thermo is designed for both built-in and concealed panel mount installation and is supplied complete with

adjustable height head. Quartz Thermo provides close temperature stability and fail safe protection when installed on

approved gravity or pumped systems and balanced high pressure systems.

A cold inlet flow regulator is provided for use with instantaneous (multipoint) gas water heater and combination boiler applications.

If you have any questions at any stage during installation please contact the Aqualisa customer helpline on 01959 560010.

Safety information

This product must be installed by a competent person in accordance with all relevant current Water Supply Regulations.

Quartz Thermo is designed for domestic use only.

Flushing

Some modern fluxes can be extremely corrosive and, if left in contact, will attack the working parts of this unit. All soldering

must be completed and the pipe work thoroughly flushed out in accordance with current Water Supply Regulations prior to

connection of the pro duct.

Connections

The Quartz Thermo valve incorporates ‘push fit’ type connections for use with 15mm British Standard copper tube. Tube

should be cut using a rotary type cutter and lubricated using a silicone based lubricant or petroleum jelly (Vaseline or similar)

prior to insertion into the fitting. Supply lines must be flushed clear of any debris before installation of the unit.

If plastic pipe is to be used, the tube insert must not increase the tube diameter or extend the cut off length by more than 2mm.

THESE FITTINGS ARE NOT SUITABLE FOR STAINLESS STEEL TUBE

Isolating valves

Suitable isolation valves such as gate valves must be fitted to both supplies in accordance with the current Water Supply

Regulations and our terms of warranty.

Due to their restrictive characteristics, stopcocks and ball type valves that reduce the pipe bore size must not be used on gravity

or pumped installations.

Filters

To ensure ongoing optimum performance the internal control

mechanism ‘cartridge’ is protected by a two-part filter system.

Debris accumulation may result in reduced flow from the shower

head and noisy operation.

As this condition is not covered by our standard warranty terms, it is

suggested that the cartridge be removed and the filters checked by

a competent person. In the event of any difficulties please contact

the Aqualisa customer helpline for assistance.

Siting

For optimum performance, with gravity fed systems, the distance between the bottom of the storage cistern and the shower

head should not be less than 1m (when using an adjustable height shower kit). If using a fixed head, the highest point of the

pipe work must be not less than 1m below the underside of the cistern. Please refer to the system layouts on page 15

Advertising