Specifications – QSC Audio CM16a User Manual

Page 34

Advertising
background image

34

Power amplifier management

Signal monitoring buses

1

(per CM16)

Number of Channels

4

Internal signal tap points

Pre-fader input signal

16

Post-fader input signal

16

Power amplifier output

16

Monitor input

Mixed with tap point signal at
unity gain

Nominal level

+4 dBu

Maximum level

+21 dBu

Input impedance

10 kOhm balanced

Configuration

Electronically balanced, shield
connected to chassis

Common-mode rejection

Typical, >50 dB, 20 Hz - 20 kHz
Worst case, >40 dB, 20 Hz-20kHz

Power amplifier interface

Compatibility

QSC Data Port equipped amplifiers

Connector and cable

HD-15 VGA cable, 2 meters length
qualified (for longer runs, contact
QSC’s Technical Services Department)

Amplifiers

Up to eight 2-Ch. amplifiers or four 4-Ch.
amplifiers ( or some combination thereof)

Amplifier status monitor

Clip indicator

Senses channel clipping

Protect indicator

Senses amplifier protect status

Temperature meter

Reports amplifier operating
temperature

Over-Temp. Alert

Software adjustable threshold

AC power control

AC mode control

Switches amplifier between
normal and standby mode

AC power indicator

Indicates operate, standby, or
power-down mode

Control room foldback monitoring

Contact closure inputs and outputs

Output

Sum of Monitor input and
signal from internal monitor
tap point

Frequency response

25 Hz–20 kHz ±0.5 dB

Distortion

<0.05% THD @ +4 dBu out

Noise floor

-90.5 dB

Nominal level

+4 dBu

Maximum level

+21 dBu

Output impedance

75 Ohms balanced

Output load

600 Ohms minimum

Configuration

Active balanced

Level

Adjusts amplitude of signal from
tap point

Monitor in to monitor out

0 dB, ±0.5 dB

Control range

-95.5 to 0 dB in 0.5 dB steps

Inputs

1 discrete input

Configuration

Single-ended input

Resistance for closure detect <1kOhm max
Resistance for open detect

>5 kOhm min

Input Voltage Limit

7.000 VDC maximum

“-” input terminal connected to chassis

Output

1 discrete output

Configuration

Electromechanical relay, dry
contacts, floating, C, NC, NO

Steady-state current (max.)

0.5 A

Switched current (max.)

0.25 A

Ground isolation

70 volts maximum

Connector

“Phoenix-style” (a.k.a.“Euro-style”)
detachable terminal block connectors

Section 4: