SECTION 5:

ARCHITECT’S AND ENGINEER’S SPECIFICATIONS

The Amplifier Network Monitor shall provide input, output,

and status control for DataPort equipped QSC power ampli-

fiers in an Ethernet-TCP/IP based network audio system.

Sixteen independent channels shall be provided, grouped in

pairs.

Amplifier Input Control and Monitoring—For each of the

sixteen power amplifier input signals, the CM16a

shall provide level, mute and polarity control, pre and

post fade signal level metering and audio monitoring,

and selectable 1Vrms or 3Vrms input sensitivity. The

Amplifier Network Monitor shall provide a page

input, separate from the normal program inputs,

whose signal may preempt the program signal of any

or all of the sixteen program channels. This input shall

have selectable 1V or 3V sensitivity.

Amplifier Output Monitoring—For each of the sixteen

power amplifier outputs, the Amplifier Network

Monitor shall provide clipping detection, short and

open circuit detection, voltage and current meter-

ing, and audio monitoring of the voltage signal.

Amplifier Management—For each of the eight DataPort

connections, the Amplifier Network Monitor shall

provide AC standby/operate mode control, AC

power state indication, temperature metering, load

status, and protect status detection.

Audio Monitoring Chain—For each of the sixteen pro-

gram channels, the Amplifier Network Monitor

shall provide three monitor points as follows: (1)

pre-fader control, (2) post-fader control, or (3) power

amplifier output. A channel’s monitor output may

be selected from one of these three signals, or it

may be switched off. The signal at the Amplifier

Network Monitor’s monitor output connector shall

be the sum of the signal at its monitor input connec-

tor and four selected (cont’d. next column-->)

channel monitor signals. A monitor gain control

shall be provided for each monitor tap point to

adjust the individual levels of the channel monitor

signals prior to their being mixed with the monitor

input signal.

Contact Closure I/O—The Amplifier Network Monitor shall

provide a trigger contact-closure sense input which

shall also be CMOS & TTL signal compatible, and

one dry-contact floating SPDT relay output.

Data Network—All Amplifier Network Monitor functions

shall be controlled and monitored via a 10

BASE

-T

Ethernet digital control network using the IP trans-

port protocol and the QSControl monitoring appli-

cation protocol. Rear-panel connection shall be

provided for 10

BASE

-T Ethernet. Other than the AC

power switch, the Amplifier Network Monitor shall

have no manual controls.

Amplifier Interface—The Amplifier Netrwork Monitor’s

interface to each power amplifier Data Port shall be

via an HD-15 connector. The amplifier interface

shall use a standard personal computer Video Graph-

ics Adapter (VGA) CRT monitor cable. This interface

shall transmit two amplifier input audio signals as

well as all control and monitoring signals. Special

signal conditioning and grounding techniques shall

be used in this interface to ensure negligible levels

of noise and crosstalk.

General—All audio inputs and outputs shall be balanced

with a nominal input level of +4 dBu and maximum

level of +21 dBu. Input connectors shall be of the

“Phoenix” detachable terminal strip type.

The Amplifier Network Monitor shall be the QSC CM16a.